2016
DOI: 10.1007/s11069-016-2641-1
|View full text |Cite
|
Sign up to set email alerts
|

Evaluating the accuracy of ANN and LR models to estimate the water quality in Zarivar International Wetland, Iran

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
8
0
2

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(13 citation statements)
references
References 66 publications
2
8
0
2
Order By: Relevance
“…The results achieved for both TSS and chlorophyll-a predictions reached a higher R 2 coefficient than research studies for the same region [20,27,48], as well as other similar studies over different areas [1,26]. Since the two studied regions present different environmental characteristics, these results indicated the soundness of the proposed method for water quality monitoring through remote sensing and ML techniques.…”
Section: Discussionsupporting
confidence: 65%
See 1 more Smart Citation
“…The results achieved for both TSS and chlorophyll-a predictions reached a higher R 2 coefficient than research studies for the same region [20,27,48], as well as other similar studies over different areas [1,26]. Since the two studied regions present different environmental characteristics, these results indicated the soundness of the proposed method for water quality monitoring through remote sensing and ML techniques.…”
Section: Discussionsupporting
confidence: 65%
“…The red channel was excluded because there are several low-cost sensors (cameras) available on the market, used in UAVs, that are modified to present the NIR channel in place of the red band. Besides that, the B, G, and NIR bands are widely used for similar applications involving chlorophyll-a [6,26] and TSS [11,26,27] prediction in water bodies. For Sentinel-2, we considered Bands 2 (Blue, 0.490 µm), 3 (Green, 0.560 µm), and 8 (NIR, 0.842 µm), which have similar bandwidths to the sensors used in the UAV.…”
Section: Remote Sensingmentioning
confidence: 99%
“…Some empirical methods have used dominant wavelengths that obtain poor accuracy, where the R 2 value is less than 0.7 on average [10,11,27]. Compared with some hyperbolic equations in describing the biological processes in wetlands, the traditional prediction method for the numerical values of COD is produced through linear regression [13,17]. Phuong et al predicted BOD and COD removals through a traditional ANN method, using either COD or BOD as input in ANN to predict the other one [25], which was cost-inefficient and time-consuming.…”
Section: Discussionmentioning
confidence: 99%
“…Estudos conduzidos por diversos pesquisadores com base em dados obtidos coletas de campo, laboratório e obtidos por sensoriamento remoto analisaram os efeitos de diferentes concentrações dos COAs na resposta espectral de corpos d'água e propõem modelos que visam estimativas de concentração dos mesmos presentes na água, através de razões de bandas (RUNDQUIST et al, 1996;GITELSON, 2006;GITELSON et al, 2007;LE et al, 2009;NOVO et al, 2013;GUO et al, 2016;AMANOLLAHI;KABOODVANDPOUR;MAJIDI, 2017), sejam elas simples, com apenas duas feições, ou mais complexas (LONDE, 2008;RUDORFF, 2006;GOODIN et al, 1993;CHENG et al, 2013;GUO et al, 2016; AMANOLLAHI; KABOODVANDPOUR; MAJIDI, 2017).…”
Section: Estudos Desenvolvidosunclassified
“…Sobre estas limitações nos estudos que visam monitorar as qualidades da água usando diferentes sensores e modelos, Amanollahi, Kabbodvandpour e Majidi (2017) destacam que a baixa qualidade de dados (relação sinal-ruído) e baixa quantificação radiométrica (inferior 12 bits) nos sensores utilizados podem ser um dos motivos para tal. Diversos autores(WATANABE et al, 2015;HA et al, 2017;AMANOLLAHI; KABOODVANDPOUR; MAJIDI, 2017) apontam que o novo sensor OLI (Operational Land Imager), a bordo do satélite Landsat 8, por apresentar alta qualidade de dados (relação sinalruído) e quantificação radiométrica (12 bits), poderia melhorar os resultados estimados de diferentes propriedades químicas e físicas da água.Em relação a utilização dos satélites Landsat para estudos de corpos d'água, Montanher, Barbosa e Novo (2013) apontam que, ao contrário dos dados de satélites como o MERIS, por exemplo, que é um sensor cujas características são adequadas aos sistemas aquáticos, os sensores da série de satélites Landsat foram desenvolvidos para aplicações relacionadas ao estudo de sistemas terrestres. No entanto, Ha et al (2017) afirmam que, embora os sensores da série Landsat não tenham sido projetados para a aplicação da qualidade da água, desde seus estágios iniciais as imagens Landsat foram extensivamente aplicadas a isso através da estimativa das concentrações de clorofila-a e fitoplâncton e o monitoramento de florações de algas e macrófitas.…”
unclassified