2017
DOI: 10.11613/bm.2017.016
|View full text |Cite
|
Sign up to set email alerts
|

Evaluating performance in sweat testing in medical biochemistry laboratories in Croatia

Abstract: IntroductionSweat test has a diagnostic role in evaluation of cystic fibrosis. Its performance includes sweat stimulation, collection and analysis. All listed may be sources of inconsistencies in everyday practice. The aim of this study was an evaluation of external quality assessment (EQA) of sweat chloride measurement including sweat test performance in medical biochemistry laboratories in Croatia.Materials and methodsEQA for sweat chloride measurement was provided by Croatian Centre for Quality Assessment i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…A survey demonstrated the need for standardising the ST at the national level because of suboptimal practices at medical biochemical laboratories (MBLs) in Croatia ( 19 ). This survey therefore laid a solid foundation for developing the NGPST.…”
Section: National Guidelines For Performance Of the Sweat Testmentioning
confidence: 99%
See 2 more Smart Citations
“…A survey demonstrated the need for standardising the ST at the national level because of suboptimal practices at medical biochemical laboratories (MBLs) in Croatia ( 19 ). This survey therefore laid a solid foundation for developing the NGPST.…”
Section: National Guidelines For Performance Of the Sweat Testmentioning
confidence: 99%
“…The NGPST were developed using questionnaires in survey conducted in 2018. The first was an update of a previously published survey covering all ST procedures ( 19 ). The second questionnaire examined the use of electrodes for PI and quality indicators, while the third investigated current power supply instruments.…”
Section: Working Group For Sweat Test Standardisation and Development...mentioning
confidence: 99%
See 1 more Smart Citation
“…Finally, it is necessary but not sufficient to organize and publish CF diagnosis consensus processes. In addition, monitoring implementation efforts and practices seem essential as recommended in the literature (41)(42)(43).…”
Section: Perspectivesmentioning
confidence: 99%