2022
DOI: 10.3390/s22218161
|View full text |Cite
|
Sign up to set email alerts
|

Evaluating a Novel Gas Sensor for Ambient Monitoring in Automated Life Science Laboratories

Abstract: Air pollution and leakages of hazardous and toxic gases and chemicals are among the dangers that frequently occur at automated chemical and life science laboratories. This type of accident needs to be processed as soon as possible to avoid the harmful side effects that can happen when a human is exposed. Nitrogen oxides and volatile organic compounds are among the most prominent indoor air pollutants, which greatly affect the lifestyles in these places. In this study, a commercial MOX gas sensor, SGP41, was em… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 17 publications
0
3
0
Order By: Relevance
“…SGP41 has a wide range of VOC gases, one of which is acetone, acetonitrile, benzene, diethyl ether, ethanol, hexane, isopropanol, methanol, and toluene where these gases are an indication of a gas leak that can spread to a fire. SGP41 can measure these gases with a fast step response time, low concentrations, and varied gas distances than the BME688 [36]. The sensors are selected based on the needs, accuracy, and range of the type of parameter measurement being detected.…”
Section: Design Systemmentioning
confidence: 99%
“…SGP41 has a wide range of VOC gases, one of which is acetone, acetonitrile, benzene, diethyl ether, ethanol, hexane, isopropanol, methanol, and toluene where these gases are an indication of a gas leak that can spread to a fire. SGP41 can measure these gases with a fast step response time, low concentrations, and varied gas distances than the BME688 [36]. The sensors are selected based on the needs, accuracy, and range of the type of parameter measurement being detected.…”
Section: Design Systemmentioning
confidence: 99%
“…Mohammed Faeik Ruzaij Al-Okby and others in 2022 [22]coordinated a commercial MOX gas sensor, SGP41, into an IoT natural sensor hub to identify and caution of perilous gasses. The analysts appeared that the sensor identified a few parameters, counting the nitrogen oxide list (NOx-Index) and the unstable natural compounds file (VOC-Index).…”
Section: Related Workmentioning
confidence: 99%
“…Moreover, this platform has been proposed as a personal environmental device with the aim of providing a cost-effective personal environmental exposure monitoring device evaluating the detrimental effects of pollutants (by measuring the levels of CO, CO 2 , O 3 , H 2 S, as well as temperature, pressure, motion, and the relative concentration of VOCs) on human health [40]. However, to the best of authors' knowledge, just a few works in the literature report systematic measurement data relevant to the BME688 sensor [33,41]. Nonetheless, it should be noted that such works focus on the behavior of the BME688 exposed to VOCs such as hexane and ethanol, while this paper is mainly concerned with the study of CO 2 concentration and of the IAQ index, together with raw data made available from the sensor including the effects of temperature and relative humidity.…”
Section: Sensors For Air Quality Evaluationmentioning