2022
DOI: 10.1016/s1470-2045(22)00447-8
|View full text |Cite|
|
Sign up to set email alerts
|

European Society for Radiotherapy and Oncology and European Organisation for Research and Treatment of Cancer consensus on re-irradiation: definition, reporting, and clinical decision making

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
34
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 48 publications
(51 citation statements)
references
References 34 publications
2
34
0
Order By: Relevance
“…[3][4][5] For the fictitious RI scenario in this study, the three re-planning strategies performed equally well (Table 2, Figure 2, Figure 3a,b), which was expected due to the large distances between PTV and relevant OARs associated with RI treatments. 1 However, note the slightly elongated EQD2 distribution for reRT reduce compared to F I G U R E 3 Dose-volume histograms (DVHs) using dose and total equivalent dose in 2-Gy fraction (EQD2 tot ) for the three relapse scenarios-repeat irradiation (RI), re-irradiation type 1 (RIT1) and type 2 (RIT2). (a): DVHs for the planning target volumes (PTV) with a broken x-axis for reRT regular (black lines), reRT reduce (red lines) and reRT voxelwise (blue lines) for all three relapse scenarios with the PTV coverage goals marked as horizontal black triangles.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…[3][4][5] For the fictitious RI scenario in this study, the three re-planning strategies performed equally well (Table 2, Figure 2, Figure 3a,b), which was expected due to the large distances between PTV and relevant OARs associated with RI treatments. 1 However, note the slightly elongated EQD2 distribution for reRT reduce compared to F I G U R E 3 Dose-volume histograms (DVHs) using dose and total equivalent dose in 2-Gy fraction (EQD2 tot ) for the three relapse scenarios-repeat irradiation (RI), re-irradiation type 1 (RIT1) and type 2 (RIT2). (a): DVHs for the planning target volumes (PTV) with a broken x-axis for reRT regular (black lines), reRT reduce (red lines) and reRT voxelwise (blue lines) for all three relapse scenarios with the PTV coverage goals marked as horizontal black triangles.…”
Section: Discussionmentioning
confidence: 99%
“…The use of EQD2 allows for dose summation of radiotherapy courses with different fractionation schedules and is often used for dose summations in re-irradiation treatments. 1,[3][4][5]10…”
Section: Re-irradiation Optimization Functionsmentioning
confidence: 99%
See 3 more Smart Citations