2014
DOI: 10.1016/j.radphyschem.2014.04.022
|View full text |Cite
|
Sign up to set email alerts
|

Etching characteristic studies for the detection of alpha particles in DAM–ADC nuclear track detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 9 publications
0
8
0
Order By: Relevance
“…One can be claimed that our new etching condition has high etching efficiency for the DAM-ADC detector at low alpha energy compared to the other conditions. Thus, we conclude that the new etching condition which introduced in this work becomes better than that used in previous works (i.e., El-Samman et al, 2014). This for the following reasons: Firstly, using mixture of NaOH and CH 3 OH reducing the etching time from 2.5 h to 1 h because of increasing in V B .…”
Section: Resultsmentioning
confidence: 58%
See 3 more Smart Citations
“…One can be claimed that our new etching condition has high etching efficiency for the DAM-ADC detector at low alpha energy compared to the other conditions. Thus, we conclude that the new etching condition which introduced in this work becomes better than that used in previous works (i.e., El-Samman et al, 2014). This for the following reasons: Firstly, using mixture of NaOH and CH 3 OH reducing the etching time from 2.5 h to 1 h because of increasing in V B .…”
Section: Resultsmentioning
confidence: 58%
“…According to Fig. 8, an increasing in sensitivity has been occurred by using our new etching conditions relative to previous etching condition (El-Samman et al, 2014). In addition, critical angle (θ c ) was determined using Eq.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The de tec tors were re moved and chem i cally etched us ing a 6.25 N so lu tion of NaOH at 70 ºC for 6 h, then CR-39 de tec tors were washed with tap wa ter for 10 min and then were put in dis tilled wa ter for 10 min and then the de tec tors were left to dry. CR-39 de tec tors were counted vi su ally us ing an op ti cal mi cro scope with a power of (400X ).The ef fi ciency of the de tec tion has been de ter mined in our pre vi ous work [11]. It was noticed that the reg is tra tion ef fi ciency of the CR-39 de tector was ap prox i mately 100 %.…”
Section: Ma Te Ri Als and Meth Odsmentioning
confidence: 99%