2012
DOI: 10.1016/j.flowmeasinst.2011.11.002
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of volume fractions and flow regime identification in multiphase flow based on gamma measurements and multivariate calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
46
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 56 publications
(49 citation statements)
references
References 15 publications
1
46
0
Order By: Relevance
“…The presented methods and described experiment, as well as attached literature, allow to formulate the following proposals: -radioisotopes may profitably supplement traditional method of multiphase flow analysis [15][16][17], -reduction of the necessary assumption demanded for radiotracer experiments allows applying easier measuring procedures and extending their range of application [18][19][20][21][22][23][24][25], -huge development in radiotracer methods, especially in flow velocity measurements, allows both reduction of the radioactivity and increase of the measurements' accuracy [20,[26][27][28][29], -in many cases, application of radioisotopes may bring smaller hazard due to mass of radioisotopes reduction [30][31][32][33], -in some measurements radiotracers may be replaced by sealed radioactive sources [10,16,26] -equipment based on a pair of sealed radioactive sources appeared to be convenient for two-phase flow control [34][35][36], -simultaneous application of tracers and sealed sources gives possibility of more detailed analysis of complex flows [37][38][39][40].…”
Section: Discussionmentioning
confidence: 99%
“…The presented methods and described experiment, as well as attached literature, allow to formulate the following proposals: -radioisotopes may profitably supplement traditional method of multiphase flow analysis [15][16][17], -reduction of the necessary assumption demanded for radiotracer experiments allows applying easier measuring procedures and extending their range of application [18][19][20][21][22][23][24][25], -huge development in radiotracer methods, especially in flow velocity measurements, allows both reduction of the radioactivity and increase of the measurements' accuracy [20,[26][27][28][29], -in many cases, application of radioisotopes may bring smaller hazard due to mass of radioisotopes reduction [30][31][32][33], -in some measurements radiotracers may be replaced by sealed radioactive sources [10,16,26] -equipment based on a pair of sealed radioactive sources appeared to be convenient for two-phase flow control [34][35][36], -simultaneous application of tracers and sealed sources gives possibility of more detailed analysis of complex flows [37][38][39][40].…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, in connection with the calibration, one may obtain the density or solid phase concentration plot [2,3].…”
Section: Density Measurementmentioning
confidence: 99%
“…For example, the size of the grains may vary and decreasing of the velocity would cause sedimentation of the solid phase. Moreover, even small modification of viscosity or the wall roughness may radically change head losses and turbulence of the flow [1,2].…”
Section: Introductionmentioning
confidence: 99%
“…The measurement of air bubbles velocity was arrange by the measuring system consisting of two 纬-radioactive sources (1) and two scintillation probes (2). The measuring set is mounted on a special trolley (8), which allows moving the set along the pipeline. Independently water flow rate was continuously measured by Uniflow 990 ultrasonic flowmeter (3).…”
Section: Gamma-absorption In Two-phase Flow Evaluation and Laboratorymentioning
confidence: 99%