2008
DOI: 10.1007/s10967-007-7147-6
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of trace levels of plutonium in urine samples by fission track technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
4
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…The detection limits set by the ICRP are 3.4 × 10 –4 Bq/L (148.4 fg/L) for 239 Pu, 2.2 × 10 –2 Bq/L (173.3 fg/L) for 241 Am, and 1.6 × 10 –1 Bq/L (53.5 fg/L) for 244 Cm in urine . However, the typical activity of TRUs in biological samples may be at the levels of femtogram. , In order to meet the requirement of detection limits in emergency situations, the need for analytical techniques with a high sample analysis throughput and a short turn-around time for the TRUs’ determination is even more pronounced.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The detection limits set by the ICRP are 3.4 × 10 –4 Bq/L (148.4 fg/L) for 239 Pu, 2.2 × 10 –2 Bq/L (173.3 fg/L) for 241 Am, and 1.6 × 10 –1 Bq/L (53.5 fg/L) for 244 Cm in urine . However, the typical activity of TRUs in biological samples may be at the levels of femtogram. , In order to meet the requirement of detection limits in emergency situations, the need for analytical techniques with a high sample analysis throughput and a short turn-around time for the TRUs’ determination is even more pronounced.…”
Section: Introductionmentioning
confidence: 99%
“…6 However, the typical activity of TRUs in biological samples may be at the levels of femtogram. 7,8 In order to meet the requirement of detection limits in emergency situations, the need for analytical techniques with a high sample analysis throughput and a short turn-around time for the TRUs' determination is even more pronounced.…”
Section: ■ Introductionmentioning
confidence: 99%
“…Urine bioassay has been regarded as a reliable approach to estimate the radiation dose of internal exposure for people occupationally or incidentally exposed to radioactive contamination. Over the past few decades, a wealth of analytical methods have been developed and applied to determine plutonium in human urine. …”
mentioning
confidence: 99%
“…Among the vast analytical methods developed for Np and Pu determination in human urine, several coprecipitation techniques have been exploited for preconcentration of target analytes, including calcium phosphate, calcium bismuth, and hydrogen titanium oxide coprecipitation. Iron hydroxide coprecipitation is a traditional method of choice for determination of trace levels Np and Pu.…”
mentioning
confidence: 99%