1992
DOI: 10.1177/039139889201501007
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of the following Cardiac Output Using Sympathetic Tone and Hemodynamics for the Control of a Total Artificial Heart

Abstract: A sympathetic neurogram is potentially useful for the development of a real time total artificial heart (TAH) control system. We used sympathetic tone and hemodynamic derivatives to estimate the following cardiac output in acute animal experiments using adult mongrel dogs. Moving averages of the mean left atrial pressure and mean aortic pressure were used as parameters of the preload and afterload, respectively. Renal sympathetic nerve activity (RSNA) was employed as a parameter of sympathetic tone. Equations … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

1999
1999
2009
2009

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 11 publications
0
8
0
Order By: Relevance
“…In this study, the functional formula for an accurate estimate of the following cardiac output was designed, and the possibility of a real-time automatic TAR control system was analyzed [13]. Seven adult mongrel dogs of both sexes weighing 15-35kg were anesthetized with thiopental sodium (2.5 mg/kg) and intravenous ketamine sodium (5.0 mg/kg).…”
Section: Prediction With Information About Sympathetic Nerve Dischargesmentioning
confidence: 99%
See 3 more Smart Citations
“…In this study, the functional formula for an accurate estimate of the following cardiac output was designed, and the possibility of a real-time automatic TAR control system was analyzed [13]. Seven adult mongrel dogs of both sexes weighing 15-35kg were anesthetized with thiopental sodium (2.5 mg/kg) and intravenous ketamine sodium (5.0 mg/kg).…”
Section: Prediction With Information About Sympathetic Nerve Dischargesmentioning
confidence: 99%
“…A variety of TAH control methods have been evaluated in various laboratories [13,14]. Many investigators have used a control algorithm based on Starling's law and others have proposed a control method in which AoP is maintained as a constant value [15].…”
Section: Future Prediction By An Autonomic Nerve and Hemodynamicsmentioning
confidence: 99%
See 2 more Smart Citations
“…Various control methods for an artificial heart have been attempted worldwide (1)(2)(3)(4)(5). First, we must achieve automatic control for the artificial heart itself (2).…”
mentioning
confidence: 99%