2008
DOI: 10.1029/2007jc004499
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of submarine groundwater discharge from bulk ground electrical conductivity measurements

Abstract: The utility of bulk ground conductivity (BGC) measurements in the estimation of submarine groundwater discharge (SGD) was investigated at four sites covering a range of hydrogeological settings, namely Cockburn Sound (Australia); Shelter Island (USA); Ubatuba Bay (Brazil) and Flic‐en‐Flac Bay (Mauritius). At each of the sites, BGC was surveyed in the intertidal zone, and seepage meters were used for direct measurements of SGD flow rates. In the presence of detectable salinity gradients in the sediment, a negat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2009
2009
2019
2019

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 33 publications
(16 citation statements)
references
References 57 publications
(108 reference statements)
0
16
0
Order By: Relevance
“…Viezzoli et al, 2010); both groundbased and airborne thermal measurements (Taniguchi, 2000;Moore et al, 2002;Johnson et al, 2008;Danielescu et al, 2009) and electrical resistivity imaging (ERI) (e.g. Swarzenski et al, 2006Swarzenski et al, , 2007Stieglitz et al, 2008;Swarzenski and Izbicki, 2009;Cardenas et al, 2010;Nakada et al, 2011). However, physical and logistical constraints may restrict the application of some of these methodologies to the study of inland CGD.…”
Section: Introductionmentioning
confidence: 99%
“…Viezzoli et al, 2010); both groundbased and airborne thermal measurements (Taniguchi, 2000;Moore et al, 2002;Johnson et al, 2008;Danielescu et al, 2009) and electrical resistivity imaging (ERI) (e.g. Swarzenski et al, 2006Swarzenski et al, , 2007Stieglitz et al, 2008;Swarzenski and Izbicki, 2009;Cardenas et al, 2010;Nakada et al, 2011). However, physical and logistical constraints may restrict the application of some of these methodologies to the study of inland CGD.…”
Section: Introductionmentioning
confidence: 99%
“…In comparison, identified ground‐based TIR anomalies along the Forge River intertidal study area were only observed adjacent to dock‐pilings (Figure b). This phenomenon has been previously observed, where anthropogenic structures act to puncture the aquifer, increasing the local hydraulic head and subsequent groundwater flow (Burnett et al ., ; Stieglitz, Rapaglia, & Bokuniewicz, ).…”
Section: Resultsmentioning
confidence: 99%
“…isotopes of the water molecule, CFCs and methane; Burnett et al 2006), geophysical and remote sensing measurements (e.g. ground conductivity and temperature; Stieglitz et al 2008;Wilson & Rocha 2012), seepage meters (e.g. Lee-type and heat-pulse seepage meters; Lee 1977; Taniguchi et al 2003) or numerical modelling (e.g.…”
Section: Discussionmentioning
confidence: 99%