2022
DOI: 10.1016/j.compbiomed.2022.105304
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of potassium levels in hemodialysis patients by T wave nonlinear dynamics and morphology markers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(15 citation statements)
references
References 43 publications
3
11
0
Order By: Relevance
“…These studies, however, have not established a tight correlation between the proposed markers and [K + ], thus limiting their possibilities for ambulatory [K + ] monitoring. In previous studies, we used nonlinear dynamics and time-warping techniques to characterize changes in the whole T wave at varying [K + ] and [Ca 2+ ] in patients and simulated ECGs [28][29][30][31][32][33]. We found a strong relationship between [K + ] and T wave linear and nonlinear features.…”
Section: Introductionmentioning
confidence: 86%
See 1 more Smart Citation
“…These studies, however, have not established a tight correlation between the proposed markers and [K + ], thus limiting their possibilities for ambulatory [K + ] monitoring. In previous studies, we used nonlinear dynamics and time-warping techniques to characterize changes in the whole T wave at varying [K + ] and [Ca 2+ ] in patients and simulated ECGs [28][29][30][31][32][33]. We found a strong relationship between [K + ] and T wave linear and nonlinear features.…”
Section: Introductionmentioning
confidence: 86%
“…A number of studies have characterized changes in T wave width, amplitude, slope or slope-to-amplitude ratio [10,11,13,49,50]. We have recently quantified changes in T wave nonlinear dynamics and morphology and have shown their relationship with [K + ] and [Ca 2+ ] variations [28,29,31,33,51].…”
Section: Characterization Of Qrs Complex Amplitude Duration and Morph...mentioning
confidence: 99%
“…81 Research in this area is ongoing; scientists are developing various algorithms in order to estimate blood potassium levels from ECG signals. 77,82,83 To date, the accuracy needed for clinical and diagnostic purposes has not been demonstrated in significant numbers of human subjects using this method.…”
Section: Non-invasive and Indirect Potassium Detectionmentioning
confidence: 99%
“…Some of the proposed T wave markers evaluated durations and slopes of the T wave or portions of it [3]. In previous studies, we investigated T wave morphology markers by using time-warping and nonlinear dynamics techniques [4][5][6].…”
Section: Introductionmentioning
confidence: 99%
“…We observed large inter-patient variability in T wave morphology in response to [K + ] and [Ca 2+ ] variations [4][5][6]. Here, we hypothesized that evaluation of T wave morphology changes using human-specific torso models could provide relevant information on inter-individual repolarization characteristics.…”
Section: Introductionmentioning
confidence: 99%