1989
DOI: 10.3109/01902148909069614
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of pH in Individual Alveolar Macrophage Phagolysosomes

Abstract: A method for measurement of phagolysosomal pH in individual alveolar macrophages based on a cytofluorometric technique with fluorescein-labeled silica particles (FSP) as a probe was developed. The size of the FSP, 3.0 or 5.0 microns, did not affect the result of the pH measurements. The average pH values, range 5.1-5.5, of individual particles in macrophages from three rabbits agreed well with the pH values obtained in a macrophage population using a fluorescence spectrometer and the FSP. The variation of pH i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
35
0

Year Published

1992
1992
2016
2016

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 47 publications
(41 citation statements)
references
References 13 publications
6
35
0
Order By: Relevance
“…Table 2 compares phagolysosomal pH obtained from measurements ofmacrophage populations by fluorescence spectrometry with measurements on single particles in phagolysosomes by fluorescence spectrometry in samples from the same rabbits. Table 2 shows a good agreement between the pH values obtained with the two methods, apparently due to the rather small variation in pH among phagolysosomes in macrophages from the same cell sample with a coefficient of variation below 10%, often only around 5% (16).…”
Section: Comparison Of Ph Obtained With Spectrometer and Microscopementioning
confidence: 77%
See 3 more Smart Citations
“…Table 2 compares phagolysosomal pH obtained from measurements ofmacrophage populations by fluorescence spectrometry with measurements on single particles in phagolysosomes by fluorescence spectrometry in samples from the same rabbits. Table 2 shows a good agreement between the pH values obtained with the two methods, apparently due to the rather small variation in pH among phagolysosomes in macrophages from the same cell sample with a coefficient of variation below 10%, often only around 5% (16).…”
Section: Comparison Of Ph Obtained With Spectrometer and Microscopementioning
confidence: 77%
“…Figure 1 show standard curves for FYP and FSP obtained from fluorescense measurements ofthe particles suspended in series of Hank's balanced salt solution (BSS) with various pHs. (14) and Nyberg et al (15,16).…”
Section: Particlesmentioning
confidence: 99%
See 2 more Smart Citations
“…range of 5 (45)(46)(47)(48)(49)(50)(51)(52)(53)(54)(55)(56)(57)(58)(59)(60), it is plausible to conclude that the intracellular mechanism of particle dissolution is controlled by these two parameters. However, at this moment we cannot exclude other mechanisms of IPD resulting from proteolytic enzymes, oxygen radicals, chelators, precipitators, etc., that are contained in the phagolysosomal plasma (20).…”
Section: Mechanisms Of Intracellular Particle Dissolutionmentioning
confidence: 99%