2011
DOI: 10.1016/j.nimb.2011.04.013
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of neutron production from accelerator head assembly of 15MV medical LINAC using FLUKA simulations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(9 citation statements)
references
References 6 publications
0
9
0
Order By: Relevance
“…Patil et al [19] describe the optimization of two foils for the flattening of electron beams at 6, 12 and 18 MeV. The primary foil is tantalum of uniform thickness, and serves to increase the lateral components of electron velocities into a Gaussian probability distribution.…”
Section: Such Validation Requires Extensive Comparisons and Iterationmentioning
confidence: 99%
See 1 more Smart Citation
“…Patil et al [19] describe the optimization of two foils for the flattening of electron beams at 6, 12 and 18 MeV. The primary foil is tantalum of uniform thickness, and serves to increase the lateral components of electron velocities into a Gaussian probability distribution.…”
Section: Such Validation Requires Extensive Comparisons and Iterationmentioning
confidence: 99%
“…We also used two sets of flattening foils, as do the Agility machines. The first foil is before the primary collimator with thickness and material based on [19] and the second foil is aluminum and constructed of three layers, of diameter and thickness based on measurements in an Elekta Agility carousel. The secondary foils are positioned 12 cm after the primary foil.…”
Section: Such Validation Requires Extensive Comparisons and Iterationmentioning
confidence: 99%
“…In the case of cancer treatments using a photon beam with an energy ≥8 MV, radiation occurs because of a chain reaction of the following two reactions [3,4]. With continuous irradiation, neutrons are generated through a photonuclear reaction (γ, n) inside the LINAC's head, and these then interact with the components inside the LINAC head, generates gamma rays [5][6][7]. The LINAC gradually becomes radioactive, exposing radiologists and patients receiving treatment to unintentional radiation [8].…”
Section: Introductionmentioning
confidence: 99%
“…and even the patient). Not only does this activation have to be taken into account for patient protection and worker dosimetry [1] [2], but also for neutron activation of the treatment head, in particular.…”
Section: Introductionmentioning
confidence: 99%