2012
DOI: 10.1088/0031-9155/57/19/6167
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of neutron-equivalent dose in organs of patients undergoing radiotherapy by the use of a novel online digital detector

Abstract: Neutron peripheral contamination in patients undergoing high-energy photon radiotherapy is considered as a risk factor for secondary cancer induction. Organ-specific neutron-equivalent dose estimation is therefore essential for a reasonable assessment of these associated risks. This work aimed to develop a method to estimate neutron-equivalent doses in multiple organs of radiotherapy patients. The method involved the convolution, at 16 reference points in an anthropomorphic phantom, of the normalized Monte Car… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
41
0
2

Year Published

2014
2014
2019
2019

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 46 publications
(43 citation statements)
references
References 25 publications
0
41
0
2
Order By: Relevance
“…Saat penyinaran pada fantom air, terjadi interaksi antara neutron cepat dengan air (H2O) yang mengakibatkan penurunan energi neutron cepat dari awal penyinaran, kemudian neutron mengalami termalisasi menjadi neutron termal. Neutron termal yang terbentuk dari reaksi ini kemudian akan mengurangi jumlah neutron termal yang berinteraksi dengan detektor, sehingga jejak yang terbaca lebih sedikit [9].…”
Section: Gambar 5 Grafik Hubungan Dosis Dan Jumlah Jejak Kalibrasi Cunclassified
“…Saat penyinaran pada fantom air, terjadi interaksi antara neutron cepat dengan air (H2O) yang mengakibatkan penurunan energi neutron cepat dari awal penyinaran, kemudian neutron mengalami termalisasi menjadi neutron termal. Neutron termal yang terbentuk dari reaksi ini kemudian akan mengurangi jumlah neutron termal yang berinteraksi dengan detektor, sehingga jejak yang terbaca lebih sedikit [9].…”
Section: Gambar 5 Grafik Hubungan Dosis Dan Jumlah Jejak Kalibrasi Cunclassified
“…Berdasarkan penelitian Sanchez [5], maka dalam penelitian ini difokuskan hanya pada daerah abdomen dekat dengan target. Dalam tulisan ini akan dipaparkan estimasi out of field doseyang diterima organ-organ kritis di sekitar target dari pesawat LINAC yang dioperasikan pada energi 15 MV melalui pengukuran.…”
Section: Data Yang Dipublikasikan Oleh Aapm (The American Associationunclassified
“…2). Results from these measurements are routinely used for peripheral neutron dose estimations, using the methodology established in Sánchez-Doblado et al (2012). Negligible photon contribution to TNRD reading was expected at this location.…”
Section: Irradiation Testsmentioning
confidence: 99%
“…These doses have two main components: leakage/scattered photons and neutron contamination. Since dosimetric methods for photon doses are well-known Taddei et al, 2013), our group has focused on the neutron component, and established a methodology to estimate peripheral neutron doses (Sánchez-Doblado et al, 2012;Expósito et al, 2013;Romero-Expósito et al, 2015;VazquezLuque et al, 2013). Although this procedure was developed for a particular thermal neutron detector (Gómez et al, 2010), could be applicable to any other (Guardiola et al, 2013;Bedogni et al, 2014).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation