Estimation of Loss of Life due to Hot Spot Development in Power Transformer using MATLAB
Abstract:The opportunity for the research in thermal modeling of power transformer is to estimate their loss of life due to overloading by employing the winding hot spot temperature (HST) and by carrying out aging studies based on heat transfer theory. This is facilitated by developing computational thermal models and their simulation using appropriate software tools. These models are employed to evaluate the actual functional age of transformers by estimating enhanced equivalent life at the reference temperature that … Show more
The aim of this paper is to determine the effects of ambient temperature variation on the breakdown voltage of a distribution transformer. Three different insulation oil samples (naphtha mineral, paraffin mineral and silicon base transformer oil) were collected from six distribution transformers (300 – 500 kVA) across two business units (Asaba and Ugbowo) of Benin Electricity Distribution Company during May and June, 2017. The oil samples were analysed using the 60 kV Megger OST60PB portable oil tester, to determine the trend of breakdown voltage of the oil insulation under varying temperature. A 3rd order polynomial model was deduced for each sample type with coefficient of determination within the range of 96.99 – 99.95 %. The observed average breakdown voltage is 43.6 kV (for naphtha base mineral transformer oil), 42.2 kV (for paraffin base mineral transformer oil) and 46.8 kV (for silicon base transformer oil) within the temperature range (26˚C – 32˚C). The result indicates that the breakdown voltages of the considered transformer oil types are satisfactory but the silicon base transformer oil has the best breakdown voltage.
The aim of this paper is to determine the effects of ambient temperature variation on the breakdown voltage of a distribution transformer. Three different insulation oil samples (naphtha mineral, paraffin mineral and silicon base transformer oil) were collected from six distribution transformers (300 – 500 kVA) across two business units (Asaba and Ugbowo) of Benin Electricity Distribution Company during May and June, 2017. The oil samples were analysed using the 60 kV Megger OST60PB portable oil tester, to determine the trend of breakdown voltage of the oil insulation under varying temperature. A 3rd order polynomial model was deduced for each sample type with coefficient of determination within the range of 96.99 – 99.95 %. The observed average breakdown voltage is 43.6 kV (for naphtha base mineral transformer oil), 42.2 kV (for paraffin base mineral transformer oil) and 46.8 kV (for silicon base transformer oil) within the temperature range (26˚C – 32˚C). The result indicates that the breakdown voltages of the considered transformer oil types are satisfactory but the silicon base transformer oil has the best breakdown voltage.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.