2008
DOI: 10.1016/j.jhydrol.2008.08.007
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of laboratory-scale dispersivities using an annulus-and-core device

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(4 citation statements)
references
References 47 publications
0
4
0
Order By: Relevance
“…Observational techniques to derive dispersion coefficients are standardized [Grane, 1961;Harleman and Rumer, 1963;Perkins and Johnston, 1963;Blackwell, 1962;Hassinger and Von Rosenberg, 1968;Han et al, 1985;Robbins, 1989;Seagren et al, 1999;Klenk and Grathwohl, 2002;Eberhardt and Grathwohl, 2002;Cirpka et al, 2006;Benekos et al, 2006;Massabo et al, 2007;Frippiat et al, 2008]. However, observations that can distinguish between spreading and mixing and identify larger scale transport processes are restricted to unconsolidated sand or bead pack models.…”
Section: Introductionmentioning
confidence: 99%
“…Observational techniques to derive dispersion coefficients are standardized [Grane, 1961;Harleman and Rumer, 1963;Perkins and Johnston, 1963;Blackwell, 1962;Hassinger and Von Rosenberg, 1968;Han et al, 1985;Robbins, 1989;Seagren et al, 1999;Klenk and Grathwohl, 2002;Eberhardt and Grathwohl, 2002;Cirpka et al, 2006;Benekos et al, 2006;Massabo et al, 2007;Frippiat et al, 2008]. However, observations that can distinguish between spreading and mixing and identify larger scale transport processes are restricted to unconsolidated sand or bead pack models.…”
Section: Introductionmentioning
confidence: 99%
“…The simulations of the tests on the other samples (sample 1, 3, 4) are performed with the calibrated values from the simulation of the test on sample 2. Case3 5e-3, (-) [18] Constitutive parameters (Eqs. 6, 17)…”
Section: Model Set-upmentioning
confidence: 99%
“…Tracer tests are most common and based on three principle techniques: (1) an annular core device with a uniform solute injected into the core region and concentration measurements of the effluent [6,27,22], (2) a device equally divided into two sides with a uniform solute injected at one-side and concentration measured using X-ray light attenuation [24], at probe locations along the core [25,26] or of the effluent [35], and (3) a device for point source injection of a solute of uniform concentration and concentration measurements taken at several points along the center line of the column [39,32]. Benekos et al [2] proposed a different technique with 70 a helix and a cochlea device.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, most of the experiments were carried out using sand [6,21,30,15,22] or bead packs [26,27,25,39,43,2,22], besides Grane [24] who determined the transverse dispersion coefficient in a Berea sandstone that is known to have homogeneous flow and transport characteristics [4].…”
Section: Introductionmentioning
confidence: 99%