2021
DOI: 10.1109/jbhi.2020.3009903
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of Instantaneous Oxygen Uptake During Exercise and Daily Activities Using a Wearable Cardio-Electromechanical and Environmental Sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(9 citation statements)
references
References 48 publications
0
9
0
Order By: Relevance
“…In parallel, we also attached the wearable patch biosensor to the subject’s mid-sternum and collected single-lead ECG, two sets of multiwavelength PPGs (red, infrared [IR], and green), and triaxial seismocardiogram (SCG, not used in this study), sampled at 500, 67, and 1000 Hz, respectively. The hardware used in the biosensor is almost identical to that reported in our previous work [ 8 , 10 , 23 ] except for the addition of the PPG modules and the change in form factor. The ECG analog front-end (AFE) and the accelerometer AFE (for SCG) remain the same.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…In parallel, we also attached the wearable patch biosensor to the subject’s mid-sternum and collected single-lead ECG, two sets of multiwavelength PPGs (red, infrared [IR], and green), and triaxial seismocardiogram (SCG, not used in this study), sampled at 500, 67, and 1000 Hz, respectively. The hardware used in the biosensor is almost identical to that reported in our previous work [ 8 , 10 , 23 ] except for the addition of the PPG modules and the change in form factor. The ECG analog front-end (AFE) and the accelerometer AFE (for SCG) remain the same.…”
Section: Methodsmentioning
confidence: 99%
“…This device is also equipped with wireless capabilities (i.e., Bluetooth and Wi-Fi) for transmitting data. However, in this study, data were stored in the Secure Digital card and later retrieved by a custom-built software application as in previous work [ 8 , 10 , 23 ]. The battery life of the device at the full sample rates of all sensors is up to 60 h. The front and lateral views of the device are shown in Figure 2 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Very recently, a different type of experimentation was reported by Shandhi et al [24]. In this work, the authors used the cardio-electromechanical and environmental sensing measurements to predict the V O .…”
Section: Exercise-based Modelsmentioning
confidence: 99%
“…The results from two different sample sizes (n = 12,480 and n = 20,868) showed reasonable predictability using the bigger sample with R = 0.87. Very recently, a different type of experimentation was reported by Shandhi et al [24]. In this work, the authors used the cardio-electromechanical and environmental sensing measurements to predict the .…”
Section: Exercise-based Modelsmentioning
confidence: 99%