2011
DOI: 10.1210/en.2011-1501
|View full text |Cite
|
Sign up to set email alerts
|

Estimation of Estradiol in Mouse Serum Samples: Evaluation of Commercial Estradiol Immunoassays

Abstract: The University of Virginia Center for Research in Reproduction Ligand Core performed an evaluation of nine commercial estradiol (E2) immunoassays for use with mouse serum. The evaluation had two components. 1) Recovery Studies: a mouse pool was spiked with E2 concentrations across the assay range, and percent recovery and parallelism to the assay standard curve were determined. 2) Correlation Studies: serum pools were collected from intact females, ovariectomized (OVX) and OVX-E2 treated mice and E2 assayed, t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

9
91
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 118 publications
(100 citation statements)
references
References 7 publications
9
91
0
Order By: Relevance
“…Our results suggest that even treatment with physiological doses of E2 in either males or females is beneficial to RV function. We elected to use the Calbiotech assay because of its excellent sensitivity and excellent performance compared with the gold standard method of gas chromatography/tandem mass spectrometry (GC/MSMS) (17). High accuracy of our measurements is demonstrated by the fact that E2 levels in our samples were consistent with levels previously reported for Sprague-Dawley rats (10,45).…”
Section: Discussionmentioning
confidence: 58%
“…Our results suggest that even treatment with physiological doses of E2 in either males or females is beneficial to RV function. We elected to use the Calbiotech assay because of its excellent sensitivity and excellent performance compared with the gold standard method of gas chromatography/tandem mass spectrometry (GC/MSMS) (17). High accuracy of our measurements is demonstrated by the fact that E2 levels in our samples were consistent with levels previously reported for Sprague-Dawley rats (10,45).…”
Section: Discussionmentioning
confidence: 58%
“…It is notable that the urinary E 2 measure was more sensitive than the serum one in Experiment 3. Some evidence has indicated that many serum enzyme-immunoassay techniques may not be sensitive in the mouse [ 30 ] . Urinary levels of E 2 are substantially higher than those of serum E 2 in the current data.…”
Section: Estradiol (Pg)/serum (Ml)mentioning
confidence: 99%
“…Although assay-dependent bias and analytical nonspecificity of direct E 2 immunoassays is established (11,12,14,15,27,(32)(33)(34)(35), direct E 2 assays are often used in research involving tissue extracts and nonhuman serum samples, where their validity is doubtful (36,37 ).…”
mentioning