2022
DOI: 10.3390/designs6040062
|View full text |Cite
|
Sign up to set email alerts
|

Estimating the Optimum Weight for Latticed Power-Transmission Towers Using Different (AI) Techniques

Abstract: The recent expansion of power-distribution networks has motivated many researchers to study how to minimize the costs of such projects. Although transmission towers present one of the main items in the network that greatly affect the project budget, there are no clear criteria or recommendations to select the optimum bracing system that minimizes the tower weight. This research presents recommendations to select the optimum configurations for latticed power-transmission towers, segment by segment, for certain … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 13 publications
(6 reference statements)
0
4
0
Order By: Relevance
“…-Conduct quality control checks for dimensions, tolerances, material properties, and welds (if applicable). (f) Documentation and Compliance: -Maintain detailed documentation of the cold-formed column installation, including design drawings, fabrication records, inspection reports, and any modifications made during the process [29]. -Ensure compliance with local building codes, regulations, and permits.…”
Section: (B) Materialsmentioning
confidence: 99%
See 3 more Smart Citations
“…-Conduct quality control checks for dimensions, tolerances, material properties, and welds (if applicable). (f) Documentation and Compliance: -Maintain detailed documentation of the cold-formed column installation, including design drawings, fabrication records, inspection reports, and any modifications made during the process [29]. -Ensure compliance with local building codes, regulations, and permits.…”
Section: (B) Materialsmentioning
confidence: 99%
“…However, the specific procedures for tracking and channeling cold-formed columns may vary depending on the project, local building codes, and industry standards. Always consult with a qualified structural engineer or design professional to ensure proper design, fabrication, and installation of cold-formed steel columns [30]. The biaxial capacity of a cold-formed steel column refers to its ability to resist combined axial and bending loads in both the major and minor axes [11,31].…”
Section: (B) Materialsmentioning
confidence: 99%
See 2 more Smart Citations