Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study

Abstract: There was no difference between groups in the use of prospective gating, tube voltage, or scan length. The examinations performed using ASIR had a lower median tube current than those obtained using FBP (median [interquartile range], 450 mA [350-600] vs 650 mA [531-750], respectively; p < 0.001). There was a 44% reduction in the median radiation dose between the FBP and ASIR cohorts (4.1 mSv [2.3-5.2] vs 2.3 mSv [1.9-3.5]; p < 0.001). After adjustment for scan settings, ASIR was associated with a 27% reduction… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
157
1
1

Year Published

2010
2010
2020
2020

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 279 publications
(165 citation statements)
references
References 22 publications
6
157
1
1
Order By: Relevance
“…Excessive image noise reduction tends to result in image blurring and resolution degradation and reconstructed images appear "artificial". Leipsic et al [20,21] who used a different iterative reconstruction technique suggested that highly iterative reconstructions produce images that are significantly different in appearance from images acquired with FBP; their noise texture appears different and their borders manifest a significantly higher degree of smoothness. Similar observations were made by Silva et al [22] who noted that noise-freeness may manifest as an artifactual over-smoothing of the image.…”
Section: Discussionmentioning
confidence: 99%
“…Excessive image noise reduction tends to result in image blurring and resolution degradation and reconstructed images appear "artificial". Leipsic et al [20,21] who used a different iterative reconstruction technique suggested that highly iterative reconstructions produce images that are significantly different in appearance from images acquired with FBP; their noise texture appears different and their borders manifest a significantly higher degree of smoothness. Similar observations were made by Silva et al [22] who noted that noise-freeness may manifest as an artifactual over-smoothing of the image.…”
Section: Discussionmentioning
confidence: 99%
“…Pilot studies with ASIR found that radiation dose can successfully be reduced by 50% in CT colonography [36], 4 ISRN Gastroenterology 44% in coronary CT angiography [37], and approximately 50% in CT abdomen and pelvis [38] without significantly affecting image quality.…”
Section: Low-dose Ct Technologymentioning
confidence: 99%
“…This technique incorporates statistical modelling to reduce image noise, which may permit preserved image quality with reduced tube current, thereby permitting lower radiation dose. As a matter of fact, first experience with statistical iterative reconstruction for coronary artery imaging has shown a 44% reduction in the median radiation dose when compared to CT protocols using filtered back projection for image reconstruction [29].…”
Section: Additional Means To Lower the Radiation Dosementioning
confidence: 99%