2020
DOI: 10.3938/jkps.76.954
|View full text |Cite
|
Sign up to set email alerts
|

Estimate of the 225Ac Radioactive Isotope Distribution by Means of DOI Compton Imaging in Targeted Alpha Radiotherapy: A Monte Carlo Simulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 28 publications
0
6
0
Order By: Relevance
“…In contrast, we present images of mice with injected activities of 20 kBq. Other works have already proposed a Compton camera for the preclinical evaluation of the daughter 221 Bi; 24,25 however, none have demonstrated the feasibility of this modality via experimentation. The most recent study by Caravaca et al 25 simulates the response Previous works have proposed and employed coded apertures for small-animal imaging, 26 but as far as we know, this work is the first to recommend a coded aperture for imaging 221 Fr via its 218-keV emission in small animals.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In contrast, we present images of mice with injected activities of 20 kBq. Other works have already proposed a Compton camera for the preclinical evaluation of the daughter 221 Bi; 24,25 however, none have demonstrated the feasibility of this modality via experimentation. The most recent study by Caravaca et al 25 simulates the response Previous works have proposed and employed coded apertures for small-animal imaging, 26 but as far as we know, this work is the first to recommend a coded aperture for imaging 221 Fr via its 218-keV emission in small animals.…”
Section: Discussionmentioning
confidence: 99%
“…Other works have already proposed a Compton camera for the preclinical evaluation of the daughter 221 Bi; 24,25 however, none have demonstrated the feasibility of this modality via experimentation. The most recent study by Caravaca et al 25 .…”
Section: Discussionmentioning
confidence: 99%
“…A new concept of high-sensitivity multipinhole collimator dedicated to TAT imaging [23] could meet the requirements, although in vivo imaging with submicrocurie doses is still to be demonstrated. Yoon et al [36] proposed a Compton camera using GAGG to image 221 Fr and 213 Bi from 225 Ac. Their tested activities (∼Mbq/ml) are three orders of magnitude higher than our targeted activities (∼kbq/ml).…”
Section: B Comparison With Other Studiesmentioning
confidence: 99%
“…The role of CZT as a high-Z scatterer is also critical, since it provides a relatively large Compton interaction rate and, at the same time, allowing for those photons to escape and to reach the absorber. Compared to GAGG [36], CZT outperforms its sensitivity, partially due to this reason. The superb energy resolution of CZT (better than most traditional scintillators [58]) is also required to obtain a high spatial resolution for Compton imaging.…”
Section: Detector Modeling Considerationsmentioning
confidence: 99%
See 1 more Smart Citation