2008
DOI: 10.1016/j.ijrobp.2007.10.037
|View full text |Cite
|
Sign up to set email alerts
|

Estimate of Radiobiologic Parameters From Clinical Data for Biologically Based Treatment Planning for Liver Irradiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
39
1

Year Published

2009
2009
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 61 publications
(44 citation statements)
references
References 33 publications
4
39
1
Order By: Relevance
“…Second, the effective number of clonogens is extremely lower than figures obtained in EBRT. Third, the obtained α′ tumour values are also extremely low, 3 to 5 times lower than those obtained from EBRT (α= 0.01/Gy [29]), and close to the values of parenchyma obtained by our group from parenchyma volume reduction. These three observations show that in glass microsphere irradiation effective values of radiobiological parameters are different from those from EBRT.…”
Section: Dose-response Correlationsupporting
confidence: 82%
See 2 more Smart Citations
“…Second, the effective number of clonogens is extremely lower than figures obtained in EBRT. Third, the obtained α′ tumour values are also extremely low, 3 to 5 times lower than those obtained from EBRT (α= 0.01/Gy [29]), and close to the values of parenchyma obtained by our group from parenchyma volume reduction. These three observations show that in glass microsphere irradiation effective values of radiobiological parameters are different from those from EBRT.…”
Section: Dose-response Correlationsupporting
confidence: 82%
“…Radiobiological parameters from EBRT seemed to provide higher AUC values. On the contrary, the TCP fit gave in all cases a radiosensitivity from 0.002/Gy to 0.006/Gy, lower and definitely incompatible with the EBRT value (α=0.01±0.001/ Gy [29]). As a test, we drew a TCP curve using α=0.01/Gy and this laid indeed too much to the left of our experimental data, with a much lower TCP50 (Fig.…”
Section: Choice Of Radiobiological Parameters: Heavy Implication On Rmentioning
confidence: 71%
See 1 more Smart Citation
“…It was suggested (15) that the normalized total dose (NTD) calculated by the linear-quadratic (LQ) model might be used to link the NTCP data from two fractionation schemes. However, this approach fails for Child-Pugh A liver patients when the dose per fraction of two fractionation schemes differs significantly (16).…”
Section: Introductionmentioning
confidence: 99%
“…d/(a/b)], we calculate that the a/b value of normal hepatocytes is between 1 and 2 Gy, which corresponds to a BED of 126-108 Gy; however, the a/b value of HCC cells is between 12 and 16 Gy, which corresponds to a BED of only 66-69. 4 Gy. This suggests that hypofractionated RT would result in the death of more healthy hepatocytes than HCC cells.…”
Section: Fractionated or Hypofractionated Dose Is Need To Weigh Thementioning
confidence: 99%