2008
DOI: 10.1109/ccece.2008.4564628
|View full text |Cite
|
Sign up to set email alerts
|

Establishment of Regulation Service market in Iran restructured power system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…These results highlight the impact of the wind generation on LFC. With fine tuning of the control parameters, the results can maintain high standards of frequency quality [8,9]. Note that PID parameters in this case are selected based on fuzzy approach.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…These results highlight the impact of the wind generation on LFC. With fine tuning of the control parameters, the results can maintain high standards of frequency quality [8,9]. Note that PID parameters in this case are selected based on fuzzy approach.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…There are, however, several issues that make this approach inappropriate for future grids. In the droop control approach, the units share active and reactive power according to pre‐specified droop characteristics, and there is always need for additional restoration control action . In spite of this, few works have reported having applied droop control to independent and variable intermittent renewable sources .…”
Section: Introductionmentioning
confidence: 99%
“…Main issue of this method was shortcoming of power in comparison with bulk power plants and industrial loads for frequency control purpose. Besides, since only one unit is in charge for frequency control there is a very poor reliability [1]. For ensuring power stability and improving quality of frequency control, in 2008 , all generation unit were obligated to activate their governor's primary control loop and corporate in frequency control.…”
Section: Current Frequency Control Methods In Iran Gridmentioning
confidence: 99%
“…Also, since only the output parameters of the units are used, no communication between the units is necessary, but there are several issues that make this method inappropriate for future smart grid. In this method the units share real and reactive power according to pre-specified droop characteristics and there is always need for additional restoration control action [1][2][3][4]. On the other hand wind energy is not constant and windmill output is proportional to the cube of wind speed, which causes the generated power of wind turbine generator (WTG) to fluctuate.…”
Section: Introductionmentioning
confidence: 99%