2015
DOI: 10.1016/j.lwt.2015.04.022
|View full text |Cite
|
Sign up to set email alerts
|

Establishment of a lateral flow colloidal gold immunoassay strip for the rapid detection of estradiol in milk samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(18 citation statements)
references
References 30 publications
(31 reference statements)
0
18
0
Order By: Relevance
“…Therefore, the polyclonal antibody was selected to develop the icELISA to detect E 2 in milk samples in term of lower IC 50 values. Our results indicated that the sensitivity of the polyclonal antibody produced in this study was among the best reported (Yang et al, 2015). The specificity of the polyclonal antibody was evaluated by comparing the IC 50 values of other structurally related compounds to that of E 2 as expressed by CR values ( Table 3).…”
Section: Development Of Icelisa In Milkmentioning
confidence: 59%
See 3 more Smart Citations
“…Therefore, the polyclonal antibody was selected to develop the icELISA to detect E 2 in milk samples in term of lower IC 50 values. Our results indicated that the sensitivity of the polyclonal antibody produced in this study was among the best reported (Yang et al, 2015). The specificity of the polyclonal antibody was evaluated by comparing the IC 50 values of other structurally related compounds to that of E 2 as expressed by CR values ( Table 3).…”
Section: Development Of Icelisa In Milkmentioning
confidence: 59%
“…Actually, there were reports showing that the antibody obtained from at 3-position were more sensitive than that obtained from 17-position of E 2 . Watanabe, Kubo, Kanzaki, and Nakazawa (2010) previously prepared β-estradiol 17-hemisuccuinate as a hapten for producing polyclonal antibodies with an IC 50 values of 6.9 ng/mL, and Yang et al (2015) synthesized E 2 -CME as a hapten for conjugating carrier proteins, obtaining a monoclonal antibody specific for E 2 with an IC 50 value of 0.18 ng/mL using a lateral-flow colloidal gold immunoassay strip. Thus, we synthesized the E 2 -CME used as hapten to produce antibodies to E 2 in this study.…”
Section: Preparation Of Haptens and Conjugatesmentioning
confidence: 99%
See 2 more Smart Citations
“…A polyvinyl chloride (PVC) backing card, an nitrocellulose (NC) membrane, the sample pad and absorption pad were assembled to prepare the lateral-flow ICA strip as described previously (Yang et al, 2015). Sample and absorbent pads were made from nonwoven, 100% pure cellulose fiber.…”
Section: Sensitivity and Specificity Of The Assaymentioning
confidence: 99%