2018
DOI: 10.1016/j.joca.2018.02.902
|View full text |Cite
|
Sign up to set email alerts
|

Establishing compositional MRI of cartilage as a biomarker for clinical practice

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
17
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 18 publications
(18 citation statements)
references
References 18 publications
1
17
0
Order By: Relevance
“…In clinical R1ρ studies at 3T, however, the spin‐lock RF strength is usually limited to 0.5 kHz, which would translate into R2-R1ρ 86%*R2aθ. On the other hand, the observed R2-R1ρ could be erroneously increased due to different data acquisitions, where R2 derived from a multiecho pulse sequence tends to be more overestimated than R1ρ from a pulse sequence similar to 3D‐MAPSS . Consequently, the enhanced R2-R1ρ could compensate for the loss due to a limited spin‐lock RF power, which might justify the comparable R2aθ and R2-R1ρ observed for some subjects in the current study.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…In clinical R1ρ studies at 3T, however, the spin‐lock RF strength is usually limited to 0.5 kHz, which would translate into R2-R1ρ 86%*R2aθ. On the other hand, the observed R2-R1ρ could be erroneously increased due to different data acquisitions, where R2 derived from a multiecho pulse sequence tends to be more overestimated than R1ρ from a pulse sequence similar to 3D‐MAPSS . Consequently, the enhanced R2-R1ρ could compensate for the loss due to a limited spin‐lock RF power, which might justify the comparable R2aθ and R2-R1ρ observed for some subjects in the current study.…”
Section: Discussionmentioning
confidence: 99%
“…As an internal reference method, the developed ARCADE mapping should alleviate any systematic errors known for both R2 and R1ρ mappings due to different pulse sequence implementations on multiple platforms, making it easier to standardize R2aθ measurement in a multicenter trial and be integrated in clinical studies. This new method is independent of the pulse sequence implementation as long as the image pixel intensities are spin‐echo weighted, which is inherently insensitive to B0 inhomogeneity.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…For osteoarthritis (OA), a recent meta‐analysis validated the reliability (compiling 58 studies) and discriminative ability (compiling 26 studies) of cartilage compositional MRI mapping in the knee, where T 2 and T 1ρ relaxometry demonstrated discrimination validity in mild OA. This can help us to detect the early stages of OA …”
mentioning
confidence: 99%