Establishing CD19 B-cell reference control materials for comparable and quantitative cytometric expression analysis

Abstract: In the field of cell-based therapeutics, there is a great need for high-quality, robust, and validated measurements for cell characterization. Flow cytometry has emerged as a critically important platform due to its high-throughput capability and its ability to simultaneously measure multiple parameters in the same sample. However, to assure the confidence in measurement, well characterized biological reference materials are needed for standardizing clinical assays and harmonizing flow cytometric results betwe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
14
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

5
2

Authors

Journals

citations
Cited by 8 publications
(17 citation statements)
references
References 52 publications
1
14
0
Order By: Relevance
“…The values of the absorption cross-section and the quantum yield would have to be changed to values appropriate for the R-PE label. The radius of the cell would have to replace the radius of the bead, and some of the flow cytometer parameters would have to be adjusted to yield the expected number of labeled CD19 antibodies on reference B cells, approximately 8000 antibodies bound per cell (ABCs) [ 15 , 16 ]. The modified model, with inclusion of electronic noise, can be used to estimate the limit of detection of R-PE label on B cells, which is expected to be on the order of 10 R-PE molecules [ 17 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The values of the absorption cross-section and the quantum yield would have to be changed to values appropriate for the R-PE label. The radius of the cell would have to replace the radius of the bead, and some of the flow cytometer parameters would have to be adjusted to yield the expected number of labeled CD19 antibodies on reference B cells, approximately 8000 antibodies bound per cell (ABCs) [ 15 , 16 ]. The modified model, with inclusion of electronic noise, can be used to estimate the limit of detection of R-PE label on B cells, which is expected to be on the order of 10 R-PE molecules [ 17 ].…”
Section: Resultsmentioning
confidence: 99%
“…The voltage pulse was digitized using an analog-to-digital converter (ADC) which sampled the voltage pulse in each of the 2 µs time bins and put out a sequence of binary digits, FI, representing the voltage. The relationship between the voltage and the FI was FI = voltage × 2 16 /5, where 2 16 /5 means that the ADC was able to split 5 V into 2 16 distinct digits. This resulted in a dynamic range of about 10 4 .…”
Section: From Cvc To a Digital Representation Of Fluorescence Intensity (Fi)mentioning
confidence: 99%
See 1 more Smart Citation
“…Physically, inequality (5) implies an event in which we track a particle starting before it enters the laser and ending after it fully exits; the corresponding function f (t) is padded on the left and right by zeros. 3 Because L 0 is constant, the locations at which we start and stop tracking the particle are fixed. Taking t = 0 as the time when the particle is at the (arbitrary) "center" z = 0 of the laser, f (t) is defined on the interval [−τ, τ ], where τ = L 0 /v.…”
Section: A Physical Effects Causing Signal Variationmentioning
confidence: 99%
“…Second, the objective has rapid oscillations due to the forms of X(v) and g(k; R). Third, in the limit that R → 0 for R/R 0 constant, the ratio g(k; R 0 )/g(k; R) → (R 0 /R) 3 , so that L Ns develops a connected set of solutions. That is, only the ratio of R 0 to R can be estimated from L Ns .…”
Section: Validation With Experimental Datamentioning
confidence: 99%