2009
DOI: 10.1016/j.apradiso.2009.01.003
|View full text |Cite
|
Sign up to set email alerts
|

ESR response of bulk samples of clear fused quartz (CFQ) material to high doses from 10MeV electrons: Its possible application for radiation processing and medical sterilization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 12 publications
(12 citation statements)
references
References 14 publications
1
10
1
Order By: Relevance
“…They also indicate that after each reuse process, the ESR response of the samples was decreased and show that the average decrease was 15.6% for the first reuse process and 18.3% for the second (both reduction values are in comparison with the first process). Similar results in our previous work about bulk samples have been observed although the amount of decrease was more than twice (37% for the first reuse process and 41% for the second reuse process of the samples in comparison to the first measurement) [16].…”
Section: Resultssupporting
confidence: 87%
See 3 more Smart Citations
“…They also indicate that after each reuse process, the ESR response of the samples was decreased and show that the average decrease was 15.6% for the first reuse process and 18.3% for the second (both reduction values are in comparison with the first process). Similar results in our previous work about bulk samples have been observed although the amount of decrease was more than twice (37% for the first reuse process and 41% for the second reuse process of the samples in comparison to the first measurement) [16].…”
Section: Resultssupporting
confidence: 87%
“…The background signal of each sample was then measured by ESR, after which they were irradiated with 10 MeV electrons. The background signals show that after annealing, the absorbed dose will become zero as reported by Ranjbar et al at normal doses with gamma rays and at high doses with 10 MeV electrons [14][15][16].…”
Section: Sample Preparation and Experimental Methodsmentioning
confidence: 58%
See 2 more Smart Citations
“…There are several methods such as electron spin resonance techniques [1], TL [2], gas chromatography [3] or DNA [4] comet assay among others that can be used for such purpose. To follow the quality of irradiated foods, some dyed polymeric films are being used for dose monitoring [5][6][7][8] during food irradiation process.…”
Section: Introductionmentioning
confidence: 99%