2022
DOI: 10.1007/s00464-022-09432-2
|View full text |Cite
|
Sign up to set email alerts
|

Esophagogastric junction compliance on impedance planimetry (EndoFLIP™) following peroral endoscopic myotomy (POEM) predicts improvement in postoperative eckardt score

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…Although FLIP measurements performed with 40 ml fill volume are considered most reliable [ 7 ], FLIP distention protocols vary across studies. In relevant studies, Ngamruenphong et al [ 5 ] registered FLIP measurements at 30 ml fill volume, Amundson et al [ 19 ] changed the FLIP protocol during their study from 30 to 40 ml fill volume, and Holmstrom et al [ 4 ] used 40 ml fill volume. Also, the reported FLIP variable differed from single-plane CSA [ 5 ] and DI [ 4 ] measurements to volume-based compliance evaluation [ 19 ].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Although FLIP measurements performed with 40 ml fill volume are considered most reliable [ 7 ], FLIP distention protocols vary across studies. In relevant studies, Ngamruenphong et al [ 5 ] registered FLIP measurements at 30 ml fill volume, Amundson et al [ 19 ] changed the FLIP protocol during their study from 30 to 40 ml fill volume, and Holmstrom et al [ 4 ] used 40 ml fill volume. Also, the reported FLIP variable differed from single-plane CSA [ 5 ] and DI [ 4 ] measurements to volume-based compliance evaluation [ 19 ].…”
Section: Discussionmentioning
confidence: 99%
“…In relevant studies, Ngamruenphong et al [ 5 ] registered FLIP measurements at 30 ml fill volume, Amundson et al [ 19 ] changed the FLIP protocol during their study from 30 to 40 ml fill volume, and Holmstrom et al [ 4 ] used 40 ml fill volume. Also, the reported FLIP variable differed from single-plane CSA [ 5 ] and DI [ 4 ] measurements to volume-based compliance evaluation [ 19 ]. These studies were all retrospective and did not include a follow-up FLIP examination.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…More than one thousand institutions worldwide were engaged in the study of POEM in treating achalasia. Among them, the top ten by the number of publications were Showa Univer-sity (69), Northwestern University (44), Asian Institute of Gastroenterology (37), Fudan University (33), University of Chicago (25), Kobe University Hospital (22), Johns Hopkins Medical Institution (21), Niigata University (20), Fukuoka University (20), and Oregon Clinic (20) (Figure 4A). In the top 10 institutions, Japan and the USA each had four organizations, while India and China each had one organization.…”
Section: Institution Analysismentioning
confidence: 99%
“…The use of intraoperative DI and cross-sectional area evaluations allowed optimization of the myotomy extent. While EndoFLIP has been used in standard esophageal POEM 3 , its potential utility may be particularly pronounced in more challenging cases.…”
mentioning
confidence: 99%