2023
DOI: 10.1039/d3an00239j
|View full text |Cite
|
Sign up to set email alerts
|

ESIPT-PET based triphenylamine-anthraquinone probe for the detection of phosgene: DFT studies, real-time application in soil samples and test strips

Abstract: The public's health and safety are gravely jeopardised by phosgene, a highly toxic gas. In this study, phosgene was detected by excited-state intramolecular proton transfer (ESIPT) and photoelectron transfer (PET)...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 66 publications
0
6
0
Order By: Relevance
“…Therefore, we used various soil samples to perform real-time research in order to gain a better knowledge of the release of phosgene into the soil. 35 A variety of soil samples were treated with phosgene dissolved in CH 3 CN ( c = 0.02 μM). The treated soils were allowed to dry for a while before being analysed with the probe DPBO ( c = 0.2 μM) (Fig.…”
Section: Practical Applicationsmentioning
confidence: 99%
“…Therefore, we used various soil samples to perform real-time research in order to gain a better knowledge of the release of phosgene into the soil. 35 A variety of soil samples were treated with phosgene dissolved in CH 3 CN ( c = 0.02 μM). The treated soils were allowed to dry for a while before being analysed with the probe DPBO ( c = 0.2 μM) (Fig.…”
Section: Practical Applicationsmentioning
confidence: 99%
“…In order to apply PBA for the practical application, soil analysis has been performed by using various soil samples like clay soil, field soil and sand, detecting Cu 2+ with soil as a medium. 35 An amount of 50 mg of the soil samples was mixed with 25 mL of double-distilled deionized water. After 10 minutes of homogenization, the homogenates were filtered and centrifuged at a high speed (5000 rpm) to get rid of any leftovers.…”
Section: Practical Applicationmentioning
confidence: 99%
“…[78,79] In 2022, Liu et al synthesized a 1,8-naphthalimide-based fluorescent probe (probe 29) to detect phosgene (Figure 14). [80] Probe 29 itself with odiaminobenzene as recognition unit has no fluorescence. However, after rapid cycled reactions with phosgene, a large fluorescence intensity increase with low LOD of 0.23 nM was generated.…”
Section: Fluorescent Probes For Detecting Methylglyoxal (Mgo) Phosgen...mentioning
confidence: 99%
“…It is worthy noting that probe 33 has good biocompatibility and can be used to test esterase within endogenous ER in living cells. [80] Copyright 2023, Elsevier.…”
Section: Fluorescent Probes For the Detection Of Lipid Droplets And E...mentioning
confidence: 99%
See 1 more Smart Citation