2018
DOI: 10.1049/iet-gtd.2017.1359
|View full text |Cite
|
Sign up to set email alerts
|

Error reduction of phasor measurement unit data considering practical constraints

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 19 publications
(7 citation statements)
references
References 25 publications
0
6
0
Order By: Relevance
“…Based on the above analysis, the conjugate symmetric data transmission path is optimized. In the actual data transmission process, the energy consumption between the same distance and different links will be different due to the influence of objective factors, so energy-based the path optimization method adds transmission consumption weights to each link, so that the network can better integrate with the objective environment in which it is located, thereby better improving the reliability of data transmission [11][12][13][14]. The transmission consumption weight matrix is as follows:…”
Section: Formulation Of Conjugate Symmetric Data Transmission Protocolmentioning
confidence: 99%
“…Based on the above analysis, the conjugate symmetric data transmission path is optimized. In the actual data transmission process, the energy consumption between the same distance and different links will be different due to the influence of objective factors, so energy-based the path optimization method adds transmission consumption weights to each link, so that the network can better integrate with the objective environment in which it is located, thereby better improving the reliability of data transmission [11][12][13][14]. The transmission consumption weight matrix is as follows:…”
Section: Formulation Of Conjugate Symmetric Data Transmission Protocolmentioning
confidence: 99%
“…The quantization behavior of the three-phase PMU output data is described in [10] [23]. All three-phase voltage and current data received by PMUs are quantized by certain scales due to the analog-to-digital conversion [24].…”
Section: ) Pmu Quantization Errormentioning
confidence: 99%
“…Proof: Let 𝜃 𝑥 𝑡 and 𝜃 𝑥 𝑚 denote the true voltage angle and the measured voltage angle, respectively, i.e. 𝜃 𝑥 𝑚 = 𝜃 𝑥 𝑡 + 𝑒 𝑥 holds true for every time instant, where 𝑒 𝑥 denotes the fixed but unknown instrumentation error [18]. Now, let a contingency occur at 𝑡 = 𝑡 𝑐 that causes the voltage angles to change in the manner shown in Fig.…”
Section: Lemma 1: Cumulative Sum Of Change In Voltage Phase Angle Com...mentioning
confidence: 99%