2020
DOI: 10.1016/j.acra.2019.06.016
|View full text |Cite
|
Sign up to set email alerts
|

Error Measurement Between Anatomical Porcine Spine, CT Images, and 3D Printing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…After, the spines were isolated from L1 to L5 and prepared in a similar way, as described in previous studies 15 . A combination of gentle sharp dissection using a scalpel, curettes, and periosteal elevators were used to remove soft tissue.…”
Section: Methodsmentioning
confidence: 99%
“…After, the spines were isolated from L1 to L5 and prepared in a similar way, as described in previous studies 15 . A combination of gentle sharp dissection using a scalpel, curettes, and periosteal elevators were used to remove soft tissue.…”
Section: Methodsmentioning
confidence: 99%
“…A region of interest was created around each individual vertebra in question, with a spacing scale of 0.8 and isotropic spacing. Cropping the region of interest reduced the amount of data in the image, and improved computer processing times 7 . Reducing the spacing scale to 0.8, before starting segmentation, changes the segmentation node's internal binary label map and increases the resolution of subsequent models in the hope this would more accurately reflect finer bone details.…”
Section: Methodsmentioning
confidence: 99%
“…To assess the accuracy of each method, eight measurements were recorded for all model types (Figure 4). Several traditional measurements from previous similar reports 7 , 8 could not be assessed due to the exclusion of the vertebral bodies and transverse processes from the segmentation. The included measurements were as follows: the left and right vertebral height, spinous process length and height, right and left pedicle height and width.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…[17][18][19] Nevertheless, an animal model can easily solve the ethical problems and frozen tissue inactivation, 20 and swine have proven to be an excellent alternative for practicing and simulating surgical strategies that cannot be performed on human cadavers. 21,22 Therefore, the primary purpose of this study was to evaluate the accuracy and repeatability of MRI VOI method by comparing the data measured by VOI with the actual forelimbs' muscle volumes of pigs. We hypothesized that the VOI method was accurate and reliable for measuring skeletal muscle volumes, and could provide a convenient and non-invasive way for clinical evaluation of sarcopenia or in orthopedics and sports medicine.…”
Section: Introductionmentioning
confidence: 99%