2021
DOI: 10.1093/ndt/gfaa322
|View full text |Cite
|
Sign up to set email alerts
|

Erratum to: Performance of Hemodialysis with Novel Medium Cut-Off Dialyzers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
1
2
0
Order By: Relevance
“…We further show that most mediators (8–42 kDa) 31 , 32 tested from dialysate samples were filtered to a greater extent during MCO versus high-flux-HD. Still, and in line with most previous data 20 , 26 , 29 we did not find superior single session elimination kinetics of MCO membranes for any mediator except YKL-40. This could be related to either the size of YKL-40 (42 kDa) or a somewhat different biologic kinetic 10 as discussed below.…”
Section: Discussionsupporting
confidence: 93%
See 1 more Smart Citation
“…We further show that most mediators (8–42 kDa) 31 , 32 tested from dialysate samples were filtered to a greater extent during MCO versus high-flux-HD. Still, and in line with most previous data 20 , 26 , 29 we did not find superior single session elimination kinetics of MCO membranes for any mediator except YKL-40. This could be related to either the size of YKL-40 (42 kDa) or a somewhat different biologic kinetic 10 as discussed below.…”
Section: Discussionsupporting
confidence: 93%
“…Other have independently reported superior and sustained (1–6 months) reduction of larger-sized middle molecules including beta-2-microglobuline (12 kDa) and λ light chain (45 kDa) during MCO versus high-flux-HD or even HDF treatment 20 , 24 , 29 , 30 . Yet, in terms of elimination of inflammatory mediators, they reached conflicting conclusions.…”
Section: Discussionmentioning
confidence: 99%
“…Compared with intermittent hemodialysis, continuous hemodialysis was hemodynamically stable. It was easy and unrestricted to adequately rehydrate, which provided better metabolic control and clearance of the body's inflammatory mediators (Kirsch et al, 2017). Lin S Y found that most scholars believed that continuous blood purification (CBP) was safe and well tolerated in patients with severe ARF, which was especially suitable for patients who were prone to hypotension and cardiac insufficiency during IHD treatment (Lin and Yi-Wen, 2018), If the patient's blood pressure is low, it may aggravate hypotension, cardiac insufficiency or arrhythmia during blood purification.…”
Section: Introductionmentioning
confidence: 99%