4th International Conference on Power Engineering, Energy and Electrical Drives 2013
DOI: 10.1109/powereng.2013.6635673
|View full text |Cite
|
Sign up to set email alerts
|

Equivalent circuit model containing AC and DC side harmonics of rectifier circuits

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 19 publications
0
3
0
Order By: Relevance
“…In order to carry out a comprehensive harmonic modeling and simulation of the Abuja Steel feeder, two categories of literatures were identified and reviewed so as to establish the gaps and come up with a more reliable result. The first group centres on harmonics modeling using traditional method otherwise called the ideal current source models [9]- [16]. Khaled, et al [9] and Ali [10] deployed the use of idealized models.…”
Section: Review Of Harmonic Modeling In Powermentioning
confidence: 99%
See 2 more Smart Citations
“…In order to carry out a comprehensive harmonic modeling and simulation of the Abuja Steel feeder, two categories of literatures were identified and reviewed so as to establish the gaps and come up with a more reliable result. The first group centres on harmonics modeling using traditional method otherwise called the ideal current source models [9]- [16]. Khaled, et al [9] and Ali [10] deployed the use of idealized models.…”
Section: Review Of Harmonic Modeling In Powermentioning
confidence: 99%
“…Similarly, DigSilent/Power factory is the simulation software used in Ma et al [13] to evaluate the future levels of harmonic distortion in a power grid based on the present harmonic current source model developed from measured data. The second group of literature review proposed the use of equivalent circuit models to represent characteristic harmonic producing loads [14]- [16]. The Norton/ Thevenin equivalent circuit provides a reliable model for harmonic current and voltage sources in a distribution network.…”
Section: Review Of Harmonic Modeling In Powermentioning
confidence: 99%
See 1 more Smart Citation
“…A matrix solution for their modeling is presented in the frequency domain in [21]. An equivalent circuit for a diode bridge that makes use of AC and DC side rectifier harmonics is given in [22]. The uncontrolled rectifiers draw non-sinusoidal currents and their current profile varies by the load power [16][17][18][19][20][21][22] and this can cause overheating in the power cables.…”
Section: Introductionmentioning
confidence: 99%
“…An equivalent circuit for a diode bridge that makes use of AC and DC side rectifier harmonics is given in [22]. The uncontrolled rectifiers draw non-sinusoidal currents and their current profile varies by the load power [16][17][18][19][20][21][22] and this can cause overheating in the power cables. In this study, a lower bound for the power loss of a three-phase power cable feeding a three-phase uncontrolled rectifier is given to find out whether the loss stays the same for the same amount of transferred power to the load and whether the loss stays within the standards such as the international electrotechnical commission IEC 60287 standard [12].…”
Section: Introductionmentioning
confidence: 99%