2010
DOI: 10.1016/j.ces.2010.03.043
|View full text |Cite
|
Sign up to set email alerts
|

Equilibrium shape and contact angle of sessile drops of different volumes—Computation by SPH and its further improvement by DI

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 31 publications
(16 citation statements)
references
References 46 publications
0
16
0
Order By: Relevance
“…Having the proper equations for implementing surface tension, now the resulting value of the contact angle should be investigated. Das et al [31,34] used CSF model for surface tension in their studies. They concluded that the resulting contact angle obtained by only applying the surface tension forces was not accurate enough and therefore suggested correcting the contact angle of the drop by repositioning the particles that form the contact line.…”
Section: Contact Angle In Sphmentioning
confidence: 99%
“…Having the proper equations for implementing surface tension, now the resulting value of the contact angle should be investigated. Das et al [31,34] used CSF model for surface tension in their studies. They concluded that the resulting contact angle obtained by only applying the surface tension forces was not accurate enough and therefore suggested correcting the contact angle of the drop by repositioning the particles that form the contact line.…”
Section: Contact Angle In Sphmentioning
confidence: 99%
“…From the common knowledge it follows that interfacial angle Θ [7][8][9] is one of the main indicators of the coal-surfactant solution-gas or the solid-surfactant solution-air interfacial interactions. The following factors influence the choice of this variable as the main for the studies [4], [5]: 1) the structure of the study solid: porosity, coal heterogeneity; 2) physical and chemical properties of the study liquid; 3) the goals and objectives of the process under consideration.…”
Section: Research Materials and Methodsmentioning
confidence: 99%
“…Using modern technical achievements, this method is also being improved, allowing on the one hand automating the measurement process and simultaneously improving the accuracy of measurements, on the other hand [7], [9],.…”
Section: Research Materials and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Our idea is to improve the existing formulation for the CSF, as a reliable tool for modelling capillary effects. We also intend to do it for a sharp interface formulation, not a diffused one like in the diffused interface approach [34]. The method proposed in the following can be summarised as: (i) simple and robust, (ii) free of scaling parameters, (iii) based purely on CSF modification, (iv) maintaining the natural interface treatment of SPH.…”
Section: Introductionmentioning
confidence: 99%