2011
DOI: 10.1080/19475411.2011.594104
|View full text |Cite
|
Sign up to set email alerts
|

Epoxy resin nanocomposites reinforced with ionized liquid stabilized carbon nanotubes

Abstract: Epoxy resin nanocomposites reinforced with three different ionic liquid functionalized carbon nanotubes (f-CNTs) were fabricated by an in situ polymerization method. The influence of the anions on the curing process was studied through differential scanning calorimetry (DSC) and normalized Fourier transform infrared (FTIR) spectroscopy. The composition of the nanocomposites was analyzed by X-ray photoelectron spectroscopy. Two different mechanisms are proposed to explain the curing process of the neat epoxy an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
26
0

Year Published

2012
2012
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 40 publications
(29 citation statements)
references
References 43 publications
3
26
0
Order By: Relevance
“…1-3). Characteristic bands belonging to CAH vibrations are observed in the regions of 2830 2 3000, 1600, 1400 2 1450 and 1375 cm 21 for aliphatic CAH stretching, aromatic C 5 C stretching, aliphatic CAH bending and CAH rock, respectively. The presence of epoxide groups is also characterized by the appearance of typical bands at 1250, 906 2 913 and 830 cm 21 ( Fig.…”
Section: Characterization Of Compositesmentioning
confidence: 99%
See 3 more Smart Citations
“…1-3). Characteristic bands belonging to CAH vibrations are observed in the regions of 2830 2 3000, 1600, 1400 2 1450 and 1375 cm 21 for aliphatic CAH stretching, aromatic C 5 C stretching, aliphatic CAH bending and CAH rock, respectively. The presence of epoxide groups is also characterized by the appearance of typical bands at 1250, 906 2 913 and 830 cm 21 ( Fig.…”
Section: Characterization Of Compositesmentioning
confidence: 99%
“…The FTIR spectra of the composites were obtained with Bruker-Platinum ATR-vertex 70 (Germany) between 500 and 4000 cm 21 wavenumbers at a resolution of 4 cm 21 using an attenuated total reflectance (ATR) accessory.…”
Section: Analysis and Testingmentioning
confidence: 99%
See 2 more Smart Citations
“…Cured EMIM/epoxy resin materials (with high IL content 17.6 phr) exhibited very low electrical network percolations; 1.7"10 -2 and 8.6"10 -5 vol% for GN and SWCNT, respectively. In literature more tedious methodology of epoxy resin/CNT/ionic liquid nanocomposite manufacturing was also reported [20,21]. Wang and Guo group applied imidazolium IL chemically functionalized CNT for epoxy nanocomposites preparation.…”
Section: Introductionmentioning
confidence: 99%