2021
DOI: 10.1016/j.radphyschem.2020.109331
|View full text |Cite
|
Sign up to set email alerts
|

EpiXS: A Windows-based program for photon attenuation, dosimetry and shielding based on EPICS2017 (ENDF/B-VIII) and EPDL97 (ENDF/B-VI.8)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
26
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 114 publications
(26 citation statements)
references
References 64 publications
0
26
0
Order By: Relevance
“…The gamma mass attenuation coefficients at the studied energies were found using Geant4. In order to validate the results, they were compared to those from EpiXS, which is a Windows-based program for photon attenuation, dosimetry, and shielding, based on the EPICS2017 and EPDL9 databases, and which allows obtaining photon cross-section data for any sample [24]. Root (6.10/04) software was used to plot the mass attenuation coefficients found using both Geant4 and EpiXS in the studied energy range, as shown in Figure 3 [23].…”
Section: Gamma Shielding Properties Of Psumentioning
confidence: 99%
“…The gamma mass attenuation coefficients at the studied energies were found using Geant4. In order to validate the results, they were compared to those from EpiXS, which is a Windows-based program for photon attenuation, dosimetry, and shielding, based on the EPICS2017 and EPDL9 databases, and which allows obtaining photon cross-section data for any sample [24]. Root (6.10/04) software was used to plot the mass attenuation coefficients found using both Geant4 and EpiXS in the studied energy range, as shown in Figure 3 [23].…”
Section: Gamma Shielding Properties Of Psumentioning
confidence: 99%
“…All the results obtained in this study are compared with powerful tools e.g. EPICS2017 [13] and Phy-X/PSD [14] that made radiation shielding parameters, and the results are found as compatible.…”
Section: Introductionmentioning
confidence: 72%
“…ACS (σT) is defined as the sum of partial cross-sections in Eq. 2.4, 𝜎 𝑇 = 𝜎 𝑃𝐸 + 𝜎 𝑐𝑜ℎ + 𝜎 𝑖𝑛𝑐𝑜ℎ + 𝜎 𝑃𝑃−𝑁 + 𝜎 𝑃𝑃−𝐸 (2.4) where σPE, σcoh, σincoh, σPP-N, and σPP-E are cross sections for photoelectric, coherent, incoherent, pair production in the nuclear field, and pair production in an electron field, respectively [19].…”
Section: Calculation Processmentioning
confidence: 99%
“…Radiation interaction coefficients of materials can be calculated by widely used codes such as XCOM [12], GEANT4 [13], WinXCom [14,15], and XMuDat [16], and recently Phy-X/PSD [17] and Py-MLBUF [18]. Among the lately reported codes, EpiXS makes it possible to determine the radiation shielding parameters such as mass attenuation coefficient, effective atomic number, electron density, atomic cross-section and buildup factors without knowing the density [19]. This feature takes the program one step ahead in terms of usability.…”
Section: Introductionmentioning
confidence: 99%