Epistemic evaluation of policy influence on workplace indoor air quality of Hong Kong in 1996—2005

Abstract: Long-term measurement results of indoor air quality (IAQ) over a general community can be used to evaluate the effectiveness of mitigation measures for IAQ improvement of premises. However, this approach requires considerable measurement efforts and thus the complete data sets are not available in many circumstances. This study proposes an epistemic approach in estimating the probable influences of an IAQ policy for Hong Kong offices, using the regional IAQ measurement databases results of IAQ in offices were … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2009
2009
2022
2022

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(15 citation statements)
references
References 16 publications
0
15
0
Order By: Relevance
“…IAQ Database A contained a total of 525 random samples of Hong Kong air-conditioned open-plan offices (of which 422 were surveyed in 2006 and 103 in 2011) taken from some previous studies [9,14,15]. The offices chosen in this database had similar building materials, style, and age so that the impact of different building factors on the pollutant sources would be minimized.…”
Section: Methodsmentioning
confidence: 99%
“…IAQ Database A contained a total of 525 random samples of Hong Kong air-conditioned open-plan offices (of which 422 were surveyed in 2006 and 103 in 2011) taken from some previous studies [9,14,15]. The offices chosen in this database had similar building materials, style, and age so that the impact of different building factors on the pollutant sources would be minimized.…”
Section: Methodsmentioning
confidence: 99%
“…An initial regional IAQ investigation at 40 selected Hong Kong air-conditioned offices was commissioned in 1995 as a consequence of the second review of the 1989 White Paper on pollution, which was issued in 1993 by the Hong Kong government [4]. This investigation result served as a legislative cornerstone of developing an indoor air pollution control policy for workplaces in Hong Kong.…”
Section: Pre-assessed Probability Of Unsatisfactory Iaqmentioning
confidence: 99%
“…Moreover, the ABCs and the formaldehyde levels had also exceeded the recommended IAQ standards. Subsequent field IAQ monitoring and Diagnostics of Unsatisfactory IAQ Indoor Built Environ 2011;20:313-320 315 assessment results in the past 10 years were reviewed and used to estimate the pre-assessed probability of unsatisfactory IAQ regarding the listed IAQ parameters [4]. Taking the exposure limits in an existing guideline as a reference, measurements in 516 offices reported that the probabilities of unsatisfactory IAQ in air-conditioned offices were less than 1% for CO, RSP, NO 2 and O 3 , 1% for Rn, 3% for CO 2 , 8% for ABC, 13% for HCHO and 16% for TVOC, respectively.…”
Section: Pre-assessed Probability Of Unsatisfactory Iaqmentioning
confidence: 99%
See 2 more Smart Citations