2012
DOI: 10.1016/j.bios.2011.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Enzymatic glucose biosensor based on CeO2 nanorods synthesized by non-isothermal precipitation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
38
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 88 publications
(39 citation statements)
references
References 30 publications
1
38
0
Order By: Relevance
“…The peaks at 28.5°, 33.3°, 47.6°, 56.5°, 58.6°, 69.1°, 76.1°, 78.6°, and 88.3° correspond to the (111), (200), (220), (311), (222), (400), (331), (420), and (422) planes of the CeO 2 crystal phase, respectively [8]. The appearance of these peaks implies that CeO 2 exhibits a cubic fluorite structure.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The peaks at 28.5°, 33.3°, 47.6°, 56.5°, 58.6°, 69.1°, 76.1°, 78.6°, and 88.3° correspond to the (111), (200), (220), (311), (222), (400), (331), (420), and (422) planes of the CeO 2 crystal phase, respectively [8]. The appearance of these peaks implies that CeO 2 exhibits a cubic fluorite structure.…”
Section: Resultsmentioning
confidence: 99%
“…Cerium oxide (CeO 2 ) is a potential material for enzymatic glucose biosensors because of its unique properties, such as chemical inertness, biocompatibility, nontoxicity, and its ability to be suitable isoelectric point for enzyme adsorption [8]. CeO 2 can highly induce electron transfer; as such, this material is a very suitable electron conductor for enzymatic biosensors.…”
Section: Introductionmentioning
confidence: 99%
“…11). The selectivity of the bioelectrode has been monitored at their physiological concentrations such as urea (1 mM), lactic acid (LA) (1 mM), cholesterol (5 mM), Linear range (mM) Sensitivity (lA mM -1 cm -2 ) References PDDA GOx/Au/CNT a 0.5-5.0 2.5 [65] GOx/Pt/FCNA/GCE b 0.5-8 6.0 [66] Nafion/GOx/Ag/Pdop c @CNT/GCE 0.05-1.1 3.1 [67] RGO/Ag/GOx 0.5-12.5 3.84 [68] GOD/CeO 2 NRs -0.165 [69] GOD-chitosan-BCNi -3.5 [70] GOD/mesoporous TiO 2 -3.9 [71] GOD/porous carbon-silica -1.8 [72] ERGO/CS/ZrO 2 /GOD 0. ascorbic acid (AA) (0.05 mM), and glucose (Glu) (5 mM). The discrepancy in the magnitude of current response was examined in PBS buffer by injecting required amount of interfering substance in equal proportion with that of glucose analyte.…”
Section: Selectivity In Terms Of Interference Studymentioning
confidence: 99%
“…The modified electrodes were further characterized by EIS and the interfacial electron transfer resistance (R et ) can be calculated from the diameter of Nyquist diagram (Musameh et al, 2011;Patil et al, 2012), so the Nyquist diagrams of different modified electrodes were recorded. As illustrated in Fig.…”
Section: Electrochemical Characterization Of the Modified Electrodesmentioning
confidence: 99%