Environmentally friendly stability-indicating HPLC method for the determination of isotretinoin in commercial products and solubility samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
1
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 46 publications
0
1
0
Order By: Relevance
“…These peaks represent different variants of the hydrolyzed gelatin molecules. Peak 6 was the most prominent peak, indicating that it represents the most abundant variant of hydrolyzed gelatin in the samples analyzed. This protocol demonstrates a refined chromatographic method for purifying hydrolyzed gelatin. The method utilizes a low TFA mobile phase for improved peak resolution and identifies specific peaks corresponding to different hydrolyzed gelatin variants.…”
Section: Resultsmentioning
confidence: 92%
“…These peaks represent different variants of the hydrolyzed gelatin molecules. Peak 6 was the most prominent peak, indicating that it represents the most abundant variant of hydrolyzed gelatin in the samples analyzed. This protocol demonstrates a refined chromatographic method for purifying hydrolyzed gelatin. The method utilizes a low TFA mobile phase for improved peak resolution and identifies specific peaks corresponding to different hydrolyzed gelatin variants.…”
Section: Resultsmentioning
confidence: 92%
“…The Analytical GREEnness (AGREE) score was determined to evaluate the eco-friendliness nature of the HPLC method. The AGREE score was predicted to be 0.76 for the present HPLC method, indicating the eco-friendly nature of the HPLC method [53]. ITN mole fraction solubilities (x e ) were calculated using their standard formulae described in our previous work [38][39][40].…”
Section: Determination Of Itn (3) Solubility In {Dmso (1) + H 2 O (2)...mentioning
confidence: 89%
“…The saturated solutions were again removed from the shaker after they had reached equilibrium and centrifuged for 30 min at 5000 rpm. A previously established environmentally friendly HPLC method was used to assess the ITN content after the supernatants were isolated and diluted (as required) [53]. The identification of ITN was carried out via a Nucleodur (dimensions: 150 mm × 4.6 mm and particle size: 5 µm) reversed-phase C 18 analytical column at 298.2 K. The environmentally friendly mobile used was a binary mixture of ethyl acetate and ethanol (50:50% v v −1 ).…”
Section: Determination Of Itn (3) Solubility In {Dmso (1) + H 2 O (2)...mentioning