2010
DOI: 10.1016/j.jhin.2010.07.010
|View full text |Cite
|
Sign up to set email alerts
|

Environmental decontamination of a hospital isolation room using high-intensity narrow-spectrum light

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
128
1
4

Year Published

2011
2011
2024
2024

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 97 publications
(134 citation statements)
references
References 15 publications
1
128
1
4
Order By: Relevance
“…With this sort of information, it is not surprising that several manufacturers are developing automated room disinfection units that demonstrate superior decontamination of environmental objects and surfaces. These systems deliver various microbicidal products, including germicidal light, hydrogen peroxide, steam, and ozone (171)(172)(173)(174)(175).…”
Section: Automated Decontamination Devicesmentioning
confidence: 99%
“…With this sort of information, it is not surprising that several manufacturers are developing automated room disinfection units that demonstrate superior decontamination of environmental objects and surfaces. These systems deliver various microbicidal products, including germicidal light, hydrogen peroxide, steam, and ozone (171)(172)(173)(174)(175).…”
Section: Automated Decontamination Devicesmentioning
confidence: 99%
“…such as using a high-intensity narrow-spectrum light en vironmental decontamination system (HINS-light EDS) 36 or ultraclean airflow mobile units. 37 Our study also shows that when contamination levels were virtually zero, almost no SSIs occurred for a total of 17 643 interventions, providing a large margin from which to safely draw our conclusions.…”
Section: Environmental Biosafety Factorsmentioning
confidence: 99%
“…Although not yet commercially available, this user-friendly, ceiling-mounted light source has been evaluated within clinical environments with successful results [57][58][59].…”
Section: Nm Violet-blue Lightmentioning
confidence: 99%
“…Studies carried out in an occupied ICU isolation room, demonstrated evidence of the efficacy of the EDS, with a significant 60 to 70% reductions in both the total viable bacterial counts (TVC) and the staphylococcal bioburden around the environment, over and above the reductions achieved by cleaning alone, with the EDS achieving an almost uniform reduction in bioburden across the room surfaces [59]. Studies conducted in Burns Unit isolation rooms also demonstrated the efficacy of the system, with 56-86% reductions in staphylococcal contamination on surfaces around isolation rooms occupied by MRSA positive patients, and up to 90% reduction of contamination after 24h use in an unoccupied room [57]. Further confirmation of the effectiveness of the system was obtained by switching off the EDS and observing that bacterial contamination levels increased and returned to around pre-treatment levels when operation of the system ceased.…”
Section: Nm Violet-blue Lightmentioning
confidence: 99%