2020
DOI: 10.1021/acscatal.0c03609
|View full text |Cite
|
Sign up to set email alerts
|

Environment Matters: CO2RR Electrocatalyst Performance Testing in a Gas-Fed Zero-Gap Electrolyzer

Abstract: Among the electrolyzers under development for CO2 electroreduction at practical reaction rates, gas-fed approaches that use gas diffusion electrodes (GDEs) as cathodes are the most promising. However, the insufficient long-term stability of these technologies precludes their commercial deployment. The structural deterioration of the catalyst material is one possible source of device durability issues. Unfortunately, this issue has been insufficiently studied in systems using actual technical electrodes. Herein… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

3
102
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 67 publications
(105 citation statements)
references
References 64 publications
3
102
0
Order By: Relevance
“…We chose a potential window for testing the CO2RR from Commercially more relevant current densities can be obtained in GDE setups, where the reactant gas does not need to be first dissolved in liquid electrolyte. To demonstrate this influence, we performed the same CO2RR studies in our recently introduced zero-gap, half-cell GDE setup 8,36 setup instead of the H-cell setup. The obtained FECO and current densities are shown in Figure 4 and Figure S7.…”
Section: Catalyst Screening Methods Influencementioning
confidence: 99%
See 2 more Smart Citations
“…We chose a potential window for testing the CO2RR from Commercially more relevant current densities can be obtained in GDE setups, where the reactant gas does not need to be first dissolved in liquid electrolyte. To demonstrate this influence, we performed the same CO2RR studies in our recently introduced zero-gap, half-cell GDE setup 8,36 setup instead of the H-cell setup. The obtained FECO and current densities are shown in Figure 4 and Figure S7.…”
Section: Catalyst Screening Methods Influencementioning
confidence: 99%
“…Our recently introduced GDE setup was employed in this study 8,36,37 the RHE conversions. Moreover, the resistance between the WE and RE and the applied electrode potentials was monitored online using an AC signal (5 kHz, 5 mV).…”
Section: Preparation Of the Gde Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…Commercially more relevant current densities can be obtained in GDE setups, where the reactant gas does not need to be first dissolved in liquid electrolyte. To demonstrate this influence, we performed the same CO2RR studies in our recently introduced zero-gap, half-cell GDE setup 8,36 setup instead of the H-cell setup. The obtained FECO and current densities are shown in Figure 4 and Figure S9.…”
Section: Catalyst Screening Methods Influencementioning
confidence: 99%
“…So doing, we can have a fairer comparison between the results of the GDE setup and the H-cell setup. Preparation of the GDE setup Our recently introduced GDE setup was employed in this study8,36,37 . As described above, the WE in the form of a GDE was placed on top of the flow field in the stainless-steel lower cell body and an activated Anion exchange membrane was placed on top of the GDE to separate the liquid electrolyte from the catalyst layer.…”
mentioning
confidence: 99%