2011
DOI: 10.1371/journal.pone.0021409
|View full text |Cite
|
Sign up to set email alerts
|

Enumeration of CD4+ T-Cells Using a Portable Microchip Count Platform in Tanzanian HIV-Infected Patients

Abstract: BackgroundCD4+ T-lymphocyte count (CD4 count) is a standard method used to monitor HIV-infected patients during anti-retroviral therapy (ART). The World Health Organization (WHO) has pointed out or recommended that a handheld, point-of-care, reliable, and affordable CD4 count platform is urgently needed in resource-scarce settings.MethodsHIV-infected patient blood samples were tested at the point-of-care using a portable and label-free microchip CD4 count platform that we have developed. A total of 130 HIV-inf… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
97
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
7

Relationship

7
0

Authors

Journals

citations
Cited by 75 publications
(97 citation statements)
references
References 20 publications
(36 reference statements)
0
97
0
Order By: Relevance
“…The device was fabricated utilizing a laser cutter, as previously described. 4,7,14,30,31 The device had outer dimensions of 25 × 40 mm. PMMA and DSA layer thicknesses were 1.5 mm and 50 µm, respectively.…”
Section: Device Fabricationmentioning
confidence: 99%
See 1 more Smart Citation
“…The device was fabricated utilizing a laser cutter, as previously described. 4,7,14,30,31 The device had outer dimensions of 25 × 40 mm. PMMA and DSA layer thicknesses were 1.5 mm and 50 µm, respectively.…”
Section: Device Fabricationmentioning
confidence: 99%
“…As such, microfluidic systems, due to their portability, affordability, and high sensitivity, have become promising technologies to develop point-of-care (POC) diagnostics. [4][5][6][7] Currently, POC diagnostics require on-chip sample processing, including plasma separation from whole blood as an initial step. 8,9 For example, inclusion of blood cells or components such as hemoglobin and lactoferrin may inhibit DNA polymerase in polymerase chain reaction (PCR) analysis and lead to inaccurate quantification or even amplification failure.…”
Section: Introductionmentioning
confidence: 99%
“…18,24,25 The device was designed with dimensions of 22 mm × 60 mm with three parallel microchannels. To assemble this device, poly(methyl methacrylate) (PMMA) (1.5 mm thick; McMaster Carr, Atlanta, GA) and doublesided adhesive film (DSA) (50 µm thick; iTapestore, Scotch Plains, NJ) were cut using a laser cutter (Versa Laser™, Scottsdale, AZ).…”
Section: Device Fabricationmentioning
confidence: 99%
“…The bacteria can be visualized either under a microscope in a laboratory setting, or for rapid counts in POC settings, with wide field of view lensless imaging systems for rapid counts for POC settings. 20,24,25,34 Also, for characterization of E. coli capture from various biological samples, we employed a GFPexpressing strain for ease of detection under a fluorescence microscope. The extension from a GFP-expressing strain to wild-type strains can be simply achieved using an ELISA-based detection method, as previously reported.…”
mentioning
confidence: 99%
See 1 more Smart Citation