2008
DOI: 10.1016/j.applthermaleng.2008.01.026
|View full text |Cite
|
Sign up to set email alerts
|

Entropy generation minimization of a double-pipe pin fin heat exchanger

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
36
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 69 publications
(36 citation statements)
references
References 12 publications
0
36
0
Order By: Relevance
“…The proposed relations (18), (27), (28), and (32) terminal temperature difference and steam condenser effectiveness were verified against data obtained from a condenser simulator (developed using a zero-dimensional steady-state model [4,[6][7][8][9]22]). The simulator was developed on the basis of commonly used correlations for the estimation of overall heat transfer coefficients for water and steam [3,4,[7][8][9]31,32].…”
Section: Entropy Generation In a Condenser And Its Connection With Itmentioning
confidence: 99%
See 3 more Smart Citations
“…The proposed relations (18), (27), (28), and (32) terminal temperature difference and steam condenser effectiveness were verified against data obtained from a condenser simulator (developed using a zero-dimensional steady-state model [4,[6][7][8][9]22]). The simulator was developed on the basis of commonly used correlations for the estimation of overall heat transfer coefficients for water and steam [3,4,[7][8][9]31,32].…”
Section: Entropy Generation In a Condenser And Its Connection With Itmentioning
confidence: 99%
“…The data shown in Fig. 3 indicate that the change in the water entropy rate is greater than the change in the steam entropy rate according to relation (27). Figure 4 shows a comparison between the condenser ratio and the ratio between the increases in steam and water specific entropies, using simulation results.…”
Section: Entropy Generation In a Condenser And Its Connection With Itmentioning
confidence: 99%
See 2 more Smart Citations
“…Also, they performed a parametric study to show the effects of bypass on the overall performance of heat sinks. Sahiti et al (2008) derived experimentally the heat transfer and pressure drop characteristics of a double-pipe pin fin heat exchanger. The researchers used the empirical correlations previously validated with their experimental data to develop a mathematical model for the optimization of the actual heat exchanger.…”
Section: şAramentioning
confidence: 99%