2018 International Russian Automation Conference (RusAutoCon) 2018
DOI: 10.1109/rusautocon.2018.8501660
|View full text |Cite
|
Sign up to set email alerts
|

Ensuring Effective Functioning of Compensating Device STATCOM in Metallurgical Enterprises

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…STATCOM system connected to "restless" 35 kV busbar, which has alternating load (arc steel furnace DSP1), providing necessary quality of electricity [14][15]. As a result of modeling [1], diagram of power supply system shown in figure 1 in Simulink Matlab package is shown in figure 2. Graph of current load on electrode terminals of arc steel furnaces is shown in figure 3.…”
Section: Theoretical Justification and Conduct Of Experimentsmentioning
confidence: 99%
See 3 more Smart Citations
“…STATCOM system connected to "restless" 35 kV busbar, which has alternating load (arc steel furnace DSP1), providing necessary quality of electricity [14][15]. As a result of modeling [1], diagram of power supply system shown in figure 1 in Simulink Matlab package is shown in figure 2. Graph of current load on electrode terminals of arc steel furnaces is shown in figure 3.…”
Section: Theoretical Justification and Conduct Of Experimentsmentioning
confidence: 99%
“…If we have a working block "Three-Phase Fault", the command to disable protected circuit will have given to "Three-Phase Breaker" element ( figure 6). In our case, shortcut circuit time starts from time t = 1.2 s, since load is modeled from previously developed model [1]. It is not difficult to notice that at time t = 1.2 s. there is a burst of amperage, accompanied by breakages of electric arcs.…”
Section: Theoretical Justification and Conduct Of Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…Many world-class enterprises have sophisticated modern reactive power compensation devices with high performance. In the article [1], ways were given to increase the performance of these devices with the elimination of false positives through statistical analysis methods. In the article [2], analysis of frequency disturbances by means of wavelet decomposition and its application in the control system of static devices were additionally considered.…”
Section: Introductionmentioning
confidence: 99%