Ultradian Rhythms From Molecules to Mind 2008
DOI: 10.1007/978-1-4020-8352-5_2
|View full text |Cite
|
Sign up to set email alerts
|

ENOX Proteins, Copper Hexahydrate-Based Ultradian Oscillators of the Cells’ Biological Clock

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
1

Year Published

2012
2012
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 86 publications
1
6
1
Order By: Relevance
“…The laser-enhanced auto-oscillations were not observed if water was irradiated beyond the oxygen absorption band or if oxygen was removed from the water. Wavelet transform analysis of the luminescence records indicated two characteristic periods of pulsations of about 300 and 1150 s. These times correspond to the oscillation periods of the concentration ratios of the ortho and para spin isomers of water molecules reported by us [3].…”
Section: Water Luminescence a Results Of Ortho-para Oscillationssupporting
confidence: 82%
See 3 more Smart Citations
“…The laser-enhanced auto-oscillations were not observed if water was irradiated beyond the oxygen absorption band or if oxygen was removed from the water. Wavelet transform analysis of the luminescence records indicated two characteristic periods of pulsations of about 300 and 1150 s. These times correspond to the oscillation periods of the concentration ratios of the ortho and para spin isomers of water molecules reported by us [3].…”
Section: Water Luminescence a Results Of Ortho-para Oscillationssupporting
confidence: 82%
“…Maxima labeled ① and ② were phased by exposure to low frequency electromagnetic fields (LFEMF) [14] with synchrony maintained over extended periods of time. The length of the period was independent of temperature suggesting a physical rather than chemical basis as the source of the oscillations [3]. , the period length is reduced from 24 min to about 18 min and maxima ④ and ⑤ are incompletely resolved to yield a 4 maxima pattern with (A) maxima ① and ② separated by 6 min and (B) maxima ③ and ④ separated from each other and from maxima ① and ② by 4 min.…”
Section: Time-keeping Enox Proteinsmentioning
confidence: 93%
See 2 more Smart Citations
“…The previously reported 18 min period for water is not an exact value but a trend in period length approximated between 18 and 20 min [5,14,19]. The findings of the present study provide a much more precise value of 18.8 min.…”
Section: Discussioncontrasting
confidence: 60%