2020
DOI: 10.1016/j.snb.2019.127340
|View full text |Cite
|
Sign up to set email alerts
|

Enhancing the sensitivity of point-of-use electrochemical microfluidic sensors by ion concentration polarisation – A case study on arsenic

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 36 publications
(20 citation statements)
references
References 44 publications
0
15
0
Order By: Relevance
“…Likewise, a stir bar coated with AuNPs and combined with a microchip device has been shown to be effective in restoring DNA multi-arm link recovery for signal transduction and amplification purposes in the rapid detection of antibiotics [ 64 ]. In addition, some microfluidic pre-concentration/amplification techniques have been applied to biological samples such as isotachophoresis (ITP) [ 120 , 121 , 122 , 123 , 124 , 125 , 126 ], ion concentration polarization (ICP) [ 127 , 128 , 129 , 130 , 131 , 132 ], electrokinetic stacking (EKS) [ 133 , 134 , 135 , 136 , 137 ], field amplification stacking (FAS) [ 138 , 139 , 140 , 141 ], and multiplex electroanalytical techniques [ 142 , 143 ]. Although it has not been applied to milk analysis, it is also an important reference for future research.…”
Section: Discussionmentioning
confidence: 99%
“…Likewise, a stir bar coated with AuNPs and combined with a microchip device has been shown to be effective in restoring DNA multi-arm link recovery for signal transduction and amplification purposes in the rapid detection of antibiotics [ 64 ]. In addition, some microfluidic pre-concentration/amplification techniques have been applied to biological samples such as isotachophoresis (ITP) [ 120 , 121 , 122 , 123 , 124 , 125 , 126 ], ion concentration polarization (ICP) [ 127 , 128 , 129 , 130 , 131 , 132 ], electrokinetic stacking (EKS) [ 133 , 134 , 135 , 136 , 137 ], field amplification stacking (FAS) [ 138 , 139 , 140 , 141 ], and multiplex electroanalytical techniques [ 142 , 143 ]. Although it has not been applied to milk analysis, it is also an important reference for future research.…”
Section: Discussionmentioning
confidence: 99%
“…In this paper, the recent progress of the ICP effect in the preconcentration of microsamples in a paper-based preconcentrator is reviewed, and the basic working principle, applications, and research progress of ICP are introduced. ICP preconcentration is also widely used in microfluidic chips on other substrates, such as PDMS [97,[119][120][121][122][123][124][125][126][127][128], polycarbonate [129], glass [127,[130][131][132][133][134][135], silicon [36,[136][137][138][139], and land hydrogels [140]. In addition, studies have been conducted on ICP preconcentration driven by ion-selective osmotic membrane pressure [141], ICP preconcentration of magnetic nanoparticles and magnets [142], etc.…”
Section: Discussionmentioning
confidence: 99%
“…As (III) was detected down to 1 µg L −1 , while the voltammogram exhibited peaks specific to ions including Cu (II), Fe (II), Mn (II), and Pb (II). The authors proposed the use of their device, in combination with a portable electrochemical analyser, as a point of use sensor for resource limited areas [165].…”
Section: Electrochemical Detection For Microfluidicsmentioning
confidence: 99%