Enhancing of Efficiency of Solar Panels Combined with Buildings Coating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…In the case when the covering is the Grafplast PDA on the solar collector and using Prandelli/Tuborama pipes with diameters of 0.016 m and 0.025 m with radiation intensities of 500 W/m 2 and 1000 W/m 2 , the efficiency of the solar collector is visible in Figures 12 and 13, respectively, when the heat carrying flow rate is equals 1-G = 0.0125 kg/s; 2-G = 0.00833 kg/s; and 3-G = 0.00417 kg/s. The analysis of diagrams (Figures [7][8][9][10][11][12][13] shows that the diameter of the tubes and the distance of their arrangement have a minor effect. That is why it is convenient to present the Grafplast-coated panel efficiency depending only on the heat flow and mass flow rate of the heat carrier.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In the case when the covering is the Grafplast PDA on the solar collector and using Prandelli/Tuborama pipes with diameters of 0.016 m and 0.025 m with radiation intensities of 500 W/m 2 and 1000 W/m 2 , the efficiency of the solar collector is visible in Figures 12 and 13, respectively, when the heat carrying flow rate is equals 1-G = 0.0125 kg/s; 2-G = 0.00833 kg/s; and 3-G = 0.00417 kg/s. The analysis of diagrams (Figures [7][8][9][10][11][12][13] shows that the diameter of the tubes and the distance of their arrangement have a minor effect. That is why it is convenient to present the Grafplast-coated panel efficiency depending only on the heat flow and mass flow rate of the heat carrier.…”
Section: Resultsmentioning
confidence: 99%
“…For conducting experimental research an experimental setup was installed at the Lviv Polytechnic National University. Its scheme is shown in Figure 4 [10]. Experimental setup included a solar collector, a heat emitter, a storage tank, shut-off and regulating valves, a flow meter and rotameter, and heat carrying medium in pipes.…”
Section: Laboratory Set Upmentioning
confidence: 99%
See 1 more Smart Citation
“…Of course, an important aspect of the building's energy efficiency remains its architectural features, in particular the size and orientation of the building block, as well as the efficiency of the operation of internal engineering networks. A smart combination of external protection and receivers of solar energy and converters of it into thermal energy allow to ensure the functioning of heating systems and hot water supply systems [1][2][3][4][5][6][7].…”
Section: Introductionmentioning
confidence: 99%