Enhancement of flow injection optosensing by sorbent extraction and reaction rate measurement

Abstract: The molybdenum blue reactlon for the determination of phosphate Is used as a model to Illustrate the extension of the use of hydrophoblc sorbents In flow Injection analyds for the preconcentratlon of an anlon and for on-cdumn detec#on, Le., optosenslng. Optosenslng provides for real-time monltorlng of the rate of slgnai change, dA /d T , so that the rate of color devebpment durlng the reductlon step of the analysis can be measured. The synerglstlc relationship between the rates of formation of the phosphate an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
15
0
2

Year Published

1991
1991
2005
2005

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 53 publications
(18 citation statements)
references
References 19 publications
1
15
0
2
Order By: Relevance
“…The MG method coupled with solvent extraction/FIA enabled to determine phosphate at several nanomolar levels of phosphorus, and was applied to river water analysis [76]: LOD was 0.1 g/l of phosphorus. The MG ion associate was enriched on-line on a solid phase, such as Shephadex (cyclodextrin derivatives) packed in a flow-through cell [77], molybdenum blue on polymer beads packed in a syringe [78] and styrene-divinylbenzene polymer packed in a short desk (1.6 mm) [79]. A signal improvement factors of 30-50 could be achieved.…”
Section: Ultratrace Analysis For Phosphorus By Flow-injection Techniquementioning
confidence: 99%
“…The MG method coupled with solvent extraction/FIA enabled to determine phosphate at several nanomolar levels of phosphorus, and was applied to river water analysis [76]: LOD was 0.1 g/l of phosphorus. The MG ion associate was enriched on-line on a solid phase, such as Shephadex (cyclodextrin derivatives) packed in a flow-through cell [77], molybdenum blue on polymer beads packed in a syringe [78] and styrene-divinylbenzene polymer packed in a short desk (1.6 mm) [79]. A signal improvement factors of 30-50 could be achieved.…”
Section: Ultratrace Analysis For Phosphorus By Flow-injection Techniquementioning
confidence: 99%
“…been found to be enhanced by detecting product directly in the column by flow injection 'optosensing' [97]. The advantages of this technique are that lower detection limits can be reached since there is no dilution during an elution step, and kinetic information can be used to discriminate interferents.…”
Section: -X8 Anion-exchange Resin Column [96] Preconcentration By Smentioning
confidence: 99%
“…Essas características são evidenciadas pelo acoplamento da EFS com sistemas de análise em fluxo (FI-EFS) 3 . Neste caso, um aumento de seletividade pode ser alcançado devido às diferenças na cinética de retenção do analito e das espécies concomitantes no suporte sólido 1,4,5 . Em procedimentos envolvendo EFS, o feixe incidente sofre tanto absorção quanto espalhamento de radiação 6 .…”
Section: Introductionunclassified
“…Entretanto, essa limitação vem sendo superada pelo emprego de lentes para a dispersão da radiação incidente, ou pelo posicionamento da cela próximo à entrada do sistema de detecção 3,6,7 . Para medidas em fluxo por espectrofotometria em fase sóli-da têm sido empregadas celas comerciais [8][9][10] ou especialmente construídas para FI-EFS 4,11 . Entretanto, celas de fluxo disponí-veis comercialmente apresentam limitações na quantidade de sólido que pode ser utilizada, podendo comprometer a sensibilidade e a faixa de resposta.…”
Section: Introductionunclassified