2020
DOI: 10.1016/j.colsurfa.2020.125285
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced simultaneous adsorption of Cd(II) and Pb(II) on octylamine functionalized vermiculite

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
8
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 34 publications
(9 citation statements)
references
References 83 publications
1
8
0
Order By: Relevance
“…The SEM results for VER and HEX are presented in (Figure S4a,d), along with an insight look through zoomed imaging in (Figure S4b,e), respectively. VER surface with tightly stacking and uniform thickness distribution (Figure S4a), turned rougher after modifying with HEX (Figure S4d), which was conducive for enhanced adsorption of heavy metal ions, due to the increase of pore diameter and active sites [38], which was in accordance with BET analysis results. Brighter areas on the surface indicate the compact and typical arrangement of aluminosilicates scattered on surface with small fragments.…”
Section: Bet Analysis and Surface Morphologysupporting
confidence: 80%
See 3 more Smart Citations
“…The SEM results for VER and HEX are presented in (Figure S4a,d), along with an insight look through zoomed imaging in (Figure S4b,e), respectively. VER surface with tightly stacking and uniform thickness distribution (Figure S4a), turned rougher after modifying with HEX (Figure S4d), which was conducive for enhanced adsorption of heavy metal ions, due to the increase of pore diameter and active sites [38], which was in accordance with BET analysis results. Brighter areas on the surface indicate the compact and typical arrangement of aluminosilicates scattered on surface with small fragments.…”
Section: Bet Analysis and Surface Morphologysupporting
confidence: 80%
“…Pseudo-first-order (PFO), and pseudo-second-order (PSO) models were used to analyze kinetic data, the equations for these models are given in Table S2. Kinetic results were in better agreement with PSO model with higher R 2 values in all systems, suggesting chemisorption process [38]. Fitting parameters are summarized in Table S6.…”
Section: Adsorption Kineticsmentioning
confidence: 57%
See 2 more Smart Citations
“…The solution pH not only affects the charges on the adsorbent surface but also affects the ionization of the solute or inhibits ions. Therefore, initial metal solution pH values that are too high should be avoided as they may cause the precipitation of metal complexes and interfere with the separation between adsorption and precipitation [23,24].…”
Section: Effects Of Process Variables On Biosorption Capacitymentioning
confidence: 99%