2009
DOI: 10.1016/j.talanta.2008.10.002
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced separation of seven quinolones by capillary electrophoresis with silica nanoparticles as additive

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
44
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 49 publications
(46 citation statements)
references
References 37 publications
1
44
0
Order By: Relevance
“…For gatifloxacin, the LOQ and LOD were 5.0 Â 10 À8 and 2.0 Â 10 À8 g/mL at S/N of 10 and 3, respectively. This analysis system for gatifloxacin shows LOQ of 1-2 orders of magnitude lower than that of most of the previously reported chromatography-based method [4][5][6][7][8][10][11][12][13].…”
Section: Methods Validationmentioning
confidence: 77%
See 3 more Smart Citations
“…For gatifloxacin, the LOQ and LOD were 5.0 Â 10 À8 and 2.0 Â 10 À8 g/mL at S/N of 10 and 3, respectively. This analysis system for gatifloxacin shows LOQ of 1-2 orders of magnitude lower than that of most of the previously reported chromatography-based method [4][5][6][7][8][10][11][12][13].…”
Section: Methods Validationmentioning
confidence: 77%
“…So far, some methods such as HPLC-UV [4][5][6][7], HPLCfluorimetry [6,8], HPLC-MS [9], CE-UV [10][11][12], highperformance TLC [13], fluorimetry [14,15], UV [16], chemiluminescent analysis [17], voltammetry [18], polarography [19], atomic absorption spectrometry [20], conductometry [20] and colorimetry [20] have been developed for the analysis of gatifloxacin in pharmaceutical preparation, biological fluid and animal tissue. Among these, HPLC [4,6,8,9] based strategies have been most universally used for the determination of this drug in biological samples since the complex matrix may severely interfere in the analysis if effective separation process is absent.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Existing methods for the determination of PZFX include high performance liquid chromatography (HPLC), [4][5][6] fluorescence method, 7 chemiluminescence, 8,9 and capillary electrophoresis. 10,11 The HPLC method with UV detector is a good method for detection with efficient separation, but the sensitivity is very low. While the fluorescence and chemiluminescence analysis methods offer high sensitivity, poor anti interference ability make them impractical for complex samples.…”
Section: Introductionmentioning
confidence: 99%