2021
DOI: 10.1016/j.ijms.2020.116471
|View full text |Cite
|
Sign up to set email alerts
|

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…These existing sample loading techniques, utilizing resin beads and porous ion emitters (PIEs) as well as running in other polyatomic forms such as oxides (e.g., NdO + rather than Nd + ), have been developed to overcome innate low ionization efficiencies (Table ). , Known strategies for increasing sample utilization efficiency for TIMS include: (1) confining the sample emission to a point source; , (2) changing the oxidation state of the sample; ,, (3) establishing a high surface area in the ion emitting region of the filament to maximize sample ionization; ,,, and (4) incorporating a high work function, highly refractory metal during the loading procedure . Resin beads, which address the first two requirements listed above, have remained nearly unchanged since first introduced in the 1970s .…”
Section: Introductionmentioning
confidence: 99%
“…These existing sample loading techniques, utilizing resin beads and porous ion emitters (PIEs) as well as running in other polyatomic forms such as oxides (e.g., NdO + rather than Nd + ), have been developed to overcome innate low ionization efficiencies (Table ). , Known strategies for increasing sample utilization efficiency for TIMS include: (1) confining the sample emission to a point source; , (2) changing the oxidation state of the sample; ,, (3) establishing a high surface area in the ion emitting region of the filament to maximize sample ionization; ,,, and (4) incorporating a high work function, highly refractory metal during the loading procedure . Resin beads, which address the first two requirements listed above, have remained nearly unchanged since first introduced in the 1970s .…”
Section: Introductionmentioning
confidence: 99%
“…Plutonium isotopes were also the focus of a study investigating solution loaded laser ablation modified sources for TIMS analysis. 202 A Parafilm coating was applied to the filament surface and then ablated through the film to the metal beneath creating a central point source. A Pu solution can then be applied to this area and slowly dried.…”
Section: Inorganic Chemicals and Materialsmentioning
confidence: 99%